Optimization of Lipid Inversion with Hyperbolic Secant Adiabatic Pulses in Transient NOE at 7T

Motivation: In vivo lipid quantification in brain tissue is challenging due to limited uniform spin inversion with conventional adiabatic pulses, affecting transient NOE (tNOE) reliability. Goal(s): Optimize B1 amplitude of hyperbolic secant (HS) adiabatic pulses in tNOE to reduce magnetization transfer (MT) effects and improve lipid quantification repeatability. Approach: Validated optimized pulse parameters on a water phantom, then acquired repeatable tNOE maps in vivo, assessing white and gray matter contrast. Results: Optimized scanner voltage (305 V) produced high-quality tNOE contrast with minimal MT interference, showing CoVs of 1% for white and 3% for gray matter. Impact: This approach may improve lipid degeneration monitoring in neurodegenerative diseases like MS and Alzheimer's.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1498
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of Lipid Inversion with Hyperbolic Secant Adiabatic Pulses in Transient NOE at 7T

Ravinder Reddy, Blake Benyard, Dushyant Kumar, Neil Wilson
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Spectroscopy Techniques in Biomedical and Chemical Research
article

Optimization of Lipid Inversion with Hyperbolic Secant Adiabatic Pulses in Transient NOE at 7T

Ravinder Reddy, Blake Benyard, Dushyant Kumar, Neil Wilson
article en

Abstract

Motivation: In vivo lipid quantification in brain tissue is challenging due to limited uniform spin inversion with conventional adiabatic pulses, affecting transient NOE (tNOE) reliability. Goal(s): Optimize B1 amplitude of hyperbolic secant (HS) adiabatic pulses in tNOE to reduce magnetization transfer (MT) effects and improve lipid quantification repeatability. Approach: Validated optimized pulse parameters on a water phantom, then acquired repeatable tNOE maps in vivo, assessing white and gray matter contrast. Results: Optimized scanner voltage (305 V) produced high-quality tNOE contrast with minimal MT interference, showing CoVs of 1% for white and 3% for gray matter. Impact: This approach may improve lipid degeneration monitoring in neurodegenerative diseases like MS and Alzheimer's.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 82%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.