Design, modeling, construction and first experimental results of the ultra high performance H12 insertable head gradient set for 10.5T

Motivation: Increased gradient performance can address several technical and physics challenges of UHF MRI. Goal(s): To develop a head gradient coil (known as H12) optimized for both PNS and magnet interaction, for insertion into the body gradient coil of a 10.5T MRI system. Approach: H12 was designed to simultaneously minimize PNS and magnet heating while fitting inside the Siemens SC72 body gradient. Results: The hardware limits of H12 exceed Gmax 200mT/m and Smax 900T/m/s using 950A, 2000V gradient drivers. Thermal results demonstrate cooling capacity >35kW. PNS thresholds should be ~10-fold higher than body gradients and up to 3-fold higher than other head gradients. Impact: H12 gradient performance (Gmax*Smax) is considerably higher than other state-of-the-art gradient coils. When combined with 10.5T B0, we expect that H12 will provide major sensitivity and resolution increases for dMRI and fMRI. Experimental results to date are confirming these expectations.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1340
Primary Topic
Superconducting Materials and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design, modeling, construction and first experimental results of the ultra high performance H12 insertable head gradient set for 10.5T

Gregor Adriany, Andrew Alejski, Koray Ertan, Brian K. Rutt et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Superconducting Materials and Applications
article

Design, modeling, construction and first experimental results of the ultra high performance H12 insertable head gradient set for 10.5T

Gregor Adriany, Andrew Alejski, Koray Ertan, Brian K. Rutt, Trevor Wade, Alexander Bratch, Edward J. Auerbach, Kâmil Uǧurbil, Peter Roemer, M.N. Bester
article en

Abstract

Motivation: Increased gradient performance can address several technical and physics challenges of UHF MRI. Goal(s): To develop a head gradient coil (known as H12) optimized for both PNS and magnet interaction, for insertion into the body gradient coil of a 10.5T MRI system. Approach: H12 was designed to simultaneously minimize PNS and magnet heating while fitting inside the Siemens SC72 body gradient. Results: The hardware limits of H12 exceed Gmax 200mT/m and Smax 900T/m/s using 950A, 2000V gradient drivers. Thermal results demonstrate cooling capacity >35kW. PNS thresholds should be ~10-fold higher than body gradients and up to 3-fold higher than other head gradients. Impact: H12 gradient performance (Gmax*Smax) is considerably higher than other state-of-the-art gradient coils. When combined with 10.5T B0, we expect that H12 will provide major sensitivity and resolution increases for dMRI and fMRI. Experimental results to date are confirming these expectations.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 76%
Superconducting Materials and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.