Investigating Liver B0 mapping at 7T: Comparison of respiration phase, shim volume size and body shim coil arrays

Motivation: Liver scanning at 7T opens new possibilities for metabolic research with greater spatial and spectral resolution and signal-to-noise ratios. However, B0 variability at 7T provides challenges for liver scanning. The addition of body shim coil arrays has been proposed to mitigate these effects. Goal(s): Assess the impact of respiration, shim volume and shim arrays on B0 inhomogeneity in the liver at 7T. Approach: B0 maps were acquired for varying shim settings and the standard deviations within a small sample volume were calculated and compared. Results: Larger shim volumes provided more uniform B0 fields. Further work is needed to optimize surface shim coil arrays. Impact: This study provides important information about the effects of respiration, shim volume size and using body shim coil arrays in 7T liver MRI/MRS. This data can be used in future studies to optimize shim routines and improve spectral line widths.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2847
Primary Topic
Liver Disease Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigating Liver B0 mapping at 7T: Comparison of respiration phase, shim volume size and body shim coil arrays

Stephen Bawden, Olivier Mougin, Susan Francis, Abi Spicer et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Liver Disease Diagnosis and Treatment
article

Investigating Liver B0 mapping at 7T: Comparison of respiration phase, shim volume size and body shim coil arrays

Stephen Bawden, Olivier Mougin, Susan Francis, Abi Spicer, Richard Bowtell, Penny Gowland
article en

Abstract

Motivation: Liver scanning at 7T opens new possibilities for metabolic research with greater spatial and spectral resolution and signal-to-noise ratios. However, B0 variability at 7T provides challenges for liver scanning. The addition of body shim coil arrays has been proposed to mitigate these effects. Goal(s): Assess the impact of respiration, shim volume and shim arrays on B0 inhomogeneity in the liver at 7T. Approach: B0 maps were acquired for varying shim settings and the standard deviations within a small sample volume were calculated and compared. Results: Larger shim volumes provided more uniform B0 fields. Further work is needed to optimize surface shim coil arrays. Impact: This study provides important information about the effects of respiration, shim volume size and using body shim coil arrays in 7T liver MRI/MRS. This data can be used in future studies to optimize shim routines and improve spectral line widths.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 66%
Liver Disease Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.