Bipolar Flip Angle Modulated Chemical Shift Encoded Imaging Enabled with Gradient Impulse Response Function

Motivation: Unipolar FAM enables motion robust CSE imaging but would benefit from shorter echo and scan times to account for PDFF quantification with a high R2*. Goal(s): We aim to develop a CSE sequence with shorter TE and scan time with robust PDFF quantification within patients. Approach: Gradient impulse response function (GIRF) was used to account for gradient-related phase errors that complicate PDFF measurements in bipolar 2D-FAM. Results: Bipolar 2D-CSE with GIRF correction enabled accurate PDFF measurement with similar results to 3D-CSE and better performance than unipolar 2D-CSE at high R2*. Impact: This study explores the application of GIRF to enable bipolar 2D-FAM for PDFF quantification. Results are comparable to conventional 3D-CSE and unipolar 2D-FAM, but yield scan time reduction, increase in R2* dynamic range, and shorter ∆TE.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2624
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bipolar Flip Angle Modulated Chemical Shift Encoded Imaging Enabled with Gradient Impulse Response Function

Diego Hernando, Jiayi Tang, Ali Pirasteh, Daiki Tamada et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Analytical Chemistry and Sensors
article

Bipolar Flip Angle Modulated Chemical Shift Encoded Imaging Enabled with Gradient Impulse Response Function

Diego Hernando, Jiayi Tang, Ali Pirasteh, Daiki Tamada, Ty Cashen, Alan B. McMillan, James Z. Wang
article en

Abstract

Motivation: Unipolar FAM enables motion robust CSE imaging but would benefit from shorter echo and scan times to account for PDFF quantification with a high R2*. Goal(s): We aim to develop a CSE sequence with shorter TE and scan time with robust PDFF quantification within patients. Approach: Gradient impulse response function (GIRF) was used to account for gradient-related phase errors that complicate PDFF measurements in bipolar 2D-FAM. Results: Bipolar 2D-CSE with GIRF correction enabled accurate PDFF measurement with similar results to 3D-CSE and better performance than unipolar 2D-CSE at high R2*. Impact: This study explores the application of GIRF to enable bipolar 2D-FAM for PDFF quantification. Results are comparable to conventional 3D-CSE and unipolar 2D-FAM, but yield scan time reduction, increase in R2* dynamic range, and shorter ∆TE.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 67%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Bipolar Flip Angle Modulated Chemical Shift Encoded Imaging Enabled with Gradient Impulse Response Function — Diego Hernando, Jiayi Tang, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS