Neonatal brain MR imaging using a dedicated 32-channel semiflexible receive coil array at 3T

Motivation: Neonatal brain MRI is the preferred modality for detecting neonatal brain injury resulting in significant neurodevelopmental disorders. Goal(s): The objective of this work is to design a 32-channel semiflexible receive coil dedicated for brain MRI in neonates within 12 months at 3T. Approach: Imaging studies in phantom and human subjects have been performed on a clinical 3T MRI system to validate the design. Results: Compared with the commercial adult head coils, the proposed coil showed performance improvement in SNR. The high-quality brain images were acquired in clinical examinations using the proposed coil, which indicated the potentiality for the application in neonatal clinical diagnosis. Impact: A 32-channel semiflexible receive coil array dedicated for brain MRI in neonates within 12 months at 3T was developed. The acquired high SNR and high-spatial resolution MR images indicated the potentiality for the application in neonatal clinical diagnosis.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2246
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Neonatal brain MR imaging using a dedicated 32-channel semiflexible receive coil array at 3T

Xianlei Meng, Feng Du, Hongwu Zeng, Ye Li et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Neonatal brain MR imaging using a dedicated 32-channel semiflexible receive coil array at 3T

Xianlei Meng, Feng Du, Hongwu Zeng, Ye Li, Xiaoliang Zhang, Nan Li, Wen Shen, Dan Fang, Yijiang Zhang
article en

Abstract

Motivation: Neonatal brain MRI is the preferred modality for detecting neonatal brain injury resulting in significant neurodevelopmental disorders. Goal(s): The objective of this work is to design a 32-channel semiflexible receive coil dedicated for brain MRI in neonates within 12 months at 3T. Approach: Imaging studies in phantom and human subjects have been performed on a clinical 3T MRI system to validate the design. Results: Compared with the commercial adult head coils, the proposed coil showed performance improvement in SNR. The high-quality brain images were acquired in clinical examinations using the proposed coil, which indicated the potentiality for the application in neonatal clinical diagnosis. Impact: A 32-channel semiflexible receive coil array dedicated for brain MRI in neonates within 12 months at 3T was developed. The acquired high SNR and high-spatial resolution MR images indicated the potentiality for the application in neonatal clinical diagnosis.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.