Optimising Ex-Vivo Hand Imaging at Ultra-High FIeld (7T)

Motivation: Ex-vivo MRI of hand specimens at ultra high field enables unprecedented, non-destructive, high resolution imaging not possible in-vivo. However, it poses a challenge requiring robust methodology and optimisation of vendor sequences that have not previously been reported. Goal(s): Our goal was to determine preparation and acquisition methods for optimised spatial resolution and contrast. Approach: Systematic testing of parameters for PD SPACE was conducted and evaluated with SNR and CNR calculations. Combinations of coils and specimen preparation methods were trialled. Results: We demonstrate optimised methodology and sequence parameter choices enabling high-resolution imaging with superior contrast in ex-vivo hand tissue. Impact: This work provides preparation methods and sequence parameters for imaging of ex-vivo hand specimens at UHF (7T) for high contrast and spatial resolution. This enables improved visualisation of anatomical detail and may be translated to other anatomical regions.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/5354
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimising Ex-Vivo Hand Imaging at Ultra-High FIeld (7T)

Bradford A. Moffat, T. Sava, Leigh A. Johnston, Rebecca Glarin et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Artificial Intelligence in Healthcare and Education
article

Optimising Ex-Vivo Hand Imaging at Ultra-High FIeld (7T)

Bradford A. Moffat, T. Sava, Leigh A. Johnston, Rebecca Glarin, Ashish Kumar Singh, Casper Thorpe Lowis, Jennifer Wilkinson-Berka
article en

Abstract

Motivation: Ex-vivo MRI of hand specimens at ultra high field enables unprecedented, non-destructive, high resolution imaging not possible in-vivo. However, it poses a challenge requiring robust methodology and optimisation of vendor sequences that have not previously been reported. Goal(s): Our goal was to determine preparation and acquisition methods for optimised spatial resolution and contrast. Approach: Systematic testing of parameters for PD SPACE was conducted and evaluated with SNR and CNR calculations. Combinations of coils and specimen preparation methods were trialled. Results: We demonstrate optimised methodology and sequence parameter choices enabling high-resolution imaging with superior contrast in ex-vivo hand tissue. Impact: This work provides preparation methods and sequence parameters for imaging of ex-vivo hand specimens at UHF (7T) for high contrast and spatial resolution. This enables improved visualisation of anatomical detail and may be translated to other anatomical regions.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 82%
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.