Ultrafast blood T1 measurement at the internal jugular vein using Golden Angle rotated Spiral k-t Sparse Parallel imaging (GASSP)

Motivation: Blood T1 measurement could be accelerated to a single-shot with Golden Angle rotated Spiral k-t Sparse Parallel imaging (GASSP), by exploiting temporal sparsity from the images acquired at successive inversion delays. Goal(s): This work aimed to apply GASSP to reduce measurement time from 60s with 6-shot to 10s with single-shot at 1mm2 in-plane resolution. Approach: On 9 healthy volunteers, GASSP was compared to the traditional EPI readout, and was repeated to assess its intra-scan reproducibility. Results: Blood T1 values measured with highly undersampled GASSP was strongly correlated with traditional EPI readout and exhibited high reproducibility. Impact: This study showed that the ultrafast (~10s) blood T1 measurement at the internal jugular vein with 1mm2 in-plane resolution using Golden Angle rotated Spiral k-t Sparse Parallel imaging (GASSP) yielded comparable performance with EPI and high intra-scan reproducibility.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2322
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrafast blood T1 measurement at the internal jugular vein using Golden Angle rotated Spiral k-t Sparse Parallel imaging (GASSP)

Dan Zhu, Zhenyu Xu, Qin Qin
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Central Venous Catheters and Hemodialysis
article

Ultrafast blood T1 measurement at the internal jugular vein using Golden Angle rotated Spiral k-t Sparse Parallel imaging (GASSP)

Dan Zhu, Zhenyu Xu, Qin Qin
article en

Abstract

Motivation: Blood T1 measurement could be accelerated to a single-shot with Golden Angle rotated Spiral k-t Sparse Parallel imaging (GASSP), by exploiting temporal sparsity from the images acquired at successive inversion delays. Goal(s): This work aimed to apply GASSP to reduce measurement time from 60s with 6-shot to 10s with single-shot at 1mm2 in-plane resolution. Approach: On 9 healthy volunteers, GASSP was compared to the traditional EPI readout, and was repeated to assess its intra-scan reproducibility. Results: Blood T1 values measured with highly undersampled GASSP was strongly correlated with traditional EPI readout and exhibited high reproducibility. Impact: This study showed that the ultrafast (~10s) blood T1 measurement at the internal jugular vein with 1mm2 in-plane resolution using Golden Angle rotated Spiral k-t Sparse Parallel imaging (GASSP) yielded comparable performance with EPI and high intra-scan reproducibility.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 62%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.