Single PD-FSE Knee MR Image Transformation Into Water, Fat and Field Inhomogeneity Images at 0.5T

Motivation: Lower SNR and closer water-fat spectral peaks at low-filed strength (74Hz at 0.5T) pose challenge to generate essential PDFS contrast in knee MRI. Dixon based methods can be used however, they need multiple MRI images increasing the scan time. Goal(s): Single image knee PDw water image at low field strength. Approach: Knee PD-FSE with shifted echo time MRI image has water and fat signal distributed in complex plane with spatially smooth field inhomogeneity. AI based method was used to solve the ill-posed problem. Results: Retrospective study over 38 patients showed similar knee PDFS MRI performance between Dixon and proposed method. Impact: Proposed method can reduce the acquisition time to obtain fat suppressed MRI at low field strength.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3099
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single PD-FSE Knee MR Image Transformation Into Water, Fat and Field Inhomogeneity Images at 0.5T

Gopal Avinash, Hongxu Yang, Lehel Ferenczi, Uday Patil et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Photoacoustic and Ultrasonic Imaging
article

Single PD-FSE Knee MR Image Transformation Into Water, Fat and Field Inhomogeneity Images at 0.5T

Gopal Avinash, Hongxu Yang, Lehel Ferenczi, Uday Patil, Harsh Agarwal, Ramesh Venkatesan
article en

Abstract

Motivation: Lower SNR and closer water-fat spectral peaks at low-filed strength (74Hz at 0.5T) pose challenge to generate essential PDFS contrast in knee MRI. Dixon based methods can be used however, they need multiple MRI images increasing the scan time. Goal(s): Single image knee PDw water image at low field strength. Approach: Knee PD-FSE with shifted echo time MRI image has water and fat signal distributed in complex plane with spatially smooth field inhomogeneity. AI based method was used to solve the ill-posed problem. Results: Retrospective study over 38 patients showed similar knee PDFS MRI performance between Dixon and proposed method. Impact: Proposed method can reduce the acquisition time to obtain fat suppressed MRI at low field strength.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 76%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.