Evaluating the Value of SEMAC-VAT with Compressed SENSE Technology in MRI Metal Artifact Reduction in Patients with Lumbar Metal Implants

Motivation: SEMAC-VAT improves imaging around metallic implants but has prolonged acquisition times. Compressed SENSE (CS) significantly reduces scan times, may address this issue. Goal(s): To evaluate the clinical utility of CS combined with SEMAC-VAT for patients with lumbar metal implants and identify the optimal CS factor. Approach: SEMAC-VAT T2 imaging utilized parallel acquisition and CS (CS4, CS6). Comparisons included implant artifact area, clarity, and diagnostic confidence. A paired t-test and Wilcoxon signed-rank test assessed acceleration factors and image quality scores. Results: SEMAC-VAT technology integrated with CS offers a promising solution for metal artifact reduction. The CS factor 4 was recommended. Impact: SEMAC-VAT technology integrated with Compressed SENSE provides a promising solution for metal artifact reduction in patients with lumbar metal implants within clinical acceptable time.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/3123
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the Value of SEMAC-VAT with Compressed SENSE Technology in MRI Metal Artifact Reduction in Patients with Lumbar Metal Implants

Hongjie Cao, Dongyu Zhao, Dandan Zheng
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced X-ray and CT Imaging
article

Evaluating the Value of SEMAC-VAT with Compressed SENSE Technology in MRI Metal Artifact Reduction in Patients with Lumbar Metal Implants

Hongjie Cao, Dongyu Zhao, Dandan Zheng
article en

Abstract

Motivation: SEMAC-VAT improves imaging around metallic implants but has prolonged acquisition times. Compressed SENSE (CS) significantly reduces scan times, may address this issue. Goal(s): To evaluate the clinical utility of CS combined with SEMAC-VAT for patients with lumbar metal implants and identify the optimal CS factor. Approach: SEMAC-VAT T2 imaging utilized parallel acquisition and CS (CS4, CS6). Comparisons included implant artifact area, clarity, and diagnostic confidence. A paired t-test and Wilcoxon signed-rank test assessed acceleration factors and image quality scores. Results: SEMAC-VAT technology integrated with CS offers a promising solution for metal artifact reduction. The CS factor 4 was recommended. Impact: SEMAC-VAT technology integrated with Compressed SENSE provides a promising solution for metal artifact reduction in patients with lumbar metal implants within clinical acceptable time.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 76%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.