The optimized double echo steady-state (DESS) sequence for T2w fluid attenuation contrast at 7T

Motivation: Three-dimensional high-resolution fluid attenuation inversion recovery (FLAIR) acquired using the SPACE sequence at 7T is challenging due to the SAR issue and B0 inhomogeneity. Goal(s): To optimize the DESS sequence for presenting a semi-FLAIR contrast Approach: The effect of the excitation FA and the spoiler gradient between the first (S_plus) echo and the second (S_minus) echo of the DESS was evaluated by EPG simulation and validated by the in vivo experiments. Results: The optimized DESS sequence (low FA of 8° and spoiler gradient) produces perfect fluid attenuation near the sphenoid sinus with a scan time of 6:30 min (0.64 mm iso). Impact: This study reported the first time the semi-FLAIR contrast at 7T without SAR limitation and B0 impact especially around sphenoid sinus using the low flip angle DESS sequence.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2590
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The optimized double echo steady-state (DESS) sequence for T2w fluid attenuation contrast at 7T

Jianxun Qu, Yi‐Cheng Hsu, Dongcui Wang, Qin Li et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

The optimized double echo steady-state (DESS) sequence for T2w fluid attenuation contrast at 7T

Jianxun Qu, Yi‐Cheng Hsu, Dongcui Wang, Qin Li, Weihua Liao, Ran Chen
article en

Abstract

Motivation: Three-dimensional high-resolution fluid attenuation inversion recovery (FLAIR) acquired using the SPACE sequence at 7T is challenging due to the SAR issue and B0 inhomogeneity. Goal(s): To optimize the DESS sequence for presenting a semi-FLAIR contrast Approach: The effect of the excitation FA and the spoiler gradient between the first (S_plus) echo and the second (S_minus) echo of the DESS was evaluated by EPG simulation and validated by the in vivo experiments. Results: The optimized DESS sequence (low FA of 8° and spoiler gradient) produces perfect fluid attenuation near the sphenoid sinus with a scan time of 6:30 min (0.64 mm iso). Impact: This study reported the first time the semi-FLAIR contrast at 7T without SAR limitation and B0 impact especially around sphenoid sinus using the low flip angle DESS sequence.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.