Improving the T1w/FLAIR ratio as a proxy for the myelin content using machine learning
Motivation: Myelin can be a useful predictor of disease progression and cognitive decline, however it requires dedicated MRI sequences. The T1w/FLAIR-ratio, which is more readily available, has previously been introduced as a proxy for the myelin content. Goal(s): To assess whether the T1w/FLAIR-ratio can be improved upon using machine learning. Approach: The T1w/FLAIR-ratio and myelin-water fraction (MWF) are calculated in a prospective (n=13) sample, and a new combination of the T1w and FLAIR ratio is calculated using a multi-layer perceptron (MLP). Results: The T1w-FLAIR combination from the MLP has a stronger correlation with MWF values in the white matter. Impact: The T1w/FLAIR-ratio can be used as a proxy for the myelin content. Here, we showed that a more optimal combination of T1w and FLAIR contrasts exist, which relates to the myelin content better.
Authors
- Jacobus F.A. Jansen (ORCID: https://orcid.org/0000-0002-5271-8060)
- Walter H. Backes (ORCID: https://orcid.org/0000-0001-7905-0681)
- Gerhard S. Drenthen (ORCID: https://orcid.org/0000-0002-7708-8501)
- J. h. Lee (ORCID: https://orcid.org/0000-0002-5574-4192)
Publication Details
- Journal
- Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
- Published
- 2025-09-16
- DOI
- https://doi.org/10.58530/2025/1597
- Primary Topic
- Radiomics and Machine Learning in Medical Imaging
- Type
- article
- Field-Weighted Citation Impact
- 0.00