R2* bias correction in brain multi-echo GRE data

Motivation: R2* mapping often suffers from artifacts from flows and field inhomogeneity. Goal(s): We propose a R2* bias correction method, targeting voxels with rapid signal decays. Approach: When the R-squared value of the fitted exponential function does not exceed a threshold, later echoes in the voxel are excluded, and the fitting is repeated. After iteration, the voxels that still do not meet the threshold are masked out. Results: The bias correction model allows us to improve R2* mapping and provides a mask for inaccurate region. Impact: Our method enhances accuracy of R2* mapping by utilizing an iterative approach which excludes the later echoes with unreliable signals. By identifying and masking out regions where correction is ineffective, the approach improves the precision of R2* values.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1705
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

R2* bias correction in brain multi-echo GRE data

Chungseok Oh, Jin Y. Choi, Taechang Kim, Jongho Lee et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

R2* bias correction in brain multi-echo GRE data

Chungseok Oh, Jin Y. Choi, Taechang Kim, Jongho Lee, Jiye Kim, Jonghyo Youn, Byeongpil Moon, Kyeongseon Min
article en

Abstract

Motivation: R2* mapping often suffers from artifacts from flows and field inhomogeneity. Goal(s): We propose a R2* bias correction method, targeting voxels with rapid signal decays. Approach: When the R-squared value of the fitted exponential function does not exceed a threshold, later echoes in the voxel are excluded, and the fitting is repeated. After iteration, the voxels that still do not meet the threshold are masked out. Results: The bias correction model allows us to improve R2* mapping and provides a mask for inaccurate region. Impact: Our method enhances accuracy of R2* mapping by utilizing an iterative approach which excludes the later echoes with unreliable signals. By identifying and masking out regions where correction is ineffective, the approach improves the precision of R2* values.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

R2* bias correction in brain multi-echo GRE data — Chungseok Oh, Jin Y. Choi, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS