TE-dependent observed lung T1 measured using inversion recovery radial turbo spin echo

Motivation: Observed lung T1 from Look-Locker inversion recovery depends on TE due to compartments in the lungs. These differ in T2* and T1, changig visible T1 dependent on TE. Goal(s): To examine further whether this dependence is due to differences in T2' or T2. Approach: Lung T1 was quantified in volunteers using inversion recovery radial TSE at 5 TIs. rTSE was acquired in free breathing using golden angle encoding. Results: Observed lung T1 was found to increase from T1(5.7ms)=985ms±69ms up to T1=1136±168ms at about TE=57ms and subsequently decreased but with greatly increased spread at longer TEs. Impact: Observed T1 in the lungs shows a dependence on TE in gradient echo sequences due to different T2* and T1 in tissue compartments. Here, we show TE-dependence due to T2 weighting and thus compartments also differ in T2.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/1879
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

TE-dependent observed lung T1 measured using inversion recovery radial turbo spin echo

Mark Oliver Wielpütz, Simon M. F. Triphan, Hans‐Ulrich Kauczor, Ke Zhang
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Atomic and Subatomic Physics Research
article

TE-dependent observed lung T1 measured using inversion recovery radial turbo spin echo

Mark Oliver Wielpütz, Simon M. F. Triphan, Hans‐Ulrich Kauczor, Ke Zhang
article en

Abstract

Motivation: Observed lung T1 from Look-Locker inversion recovery depends on TE due to compartments in the lungs. These differ in T2* and T1, changig visible T1 dependent on TE. Goal(s): To examine further whether this dependence is due to differences in T2' or T2. Approach: Lung T1 was quantified in volunteers using inversion recovery radial TSE at 5 TIs. rTSE was acquired in free breathing using golden angle encoding. Results: Observed lung T1 was found to increase from T1(5.7ms)=985ms±69ms up to T1=1136±168ms at about TE=57ms and subsequently decreased but with greatly increased spread at longer TEs. Impact: Observed T1 in the lungs shows a dependence on TE in gradient echo sequences due to different T2* and T1 in tissue compartments. Here, we show TE-dependence due to T2 weighting and thus compartments also differ in T2.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 81%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

TE-dependent observed lung T1 measured using inversion recovery radial turbo spin echo — Mark Oliver Wielpütz, Simon M. F. Triphan, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS