Temperature Mapping During MR-Guided Cryoablation Using a FLORET UTE Sequence

Motivation: Frozen tissue has a rapid T2* decay and low net magnetization. It thus appears as a signal void in most MR images. As tissue necrosis only happens between -20 and -40 °C it is not possible to distinguish between frozen and necrotic tissue during MR-guided cryoablation. Goal(s): Our goal was to estimate temperatures in frozen tissue. Approach: To encounter the rapid T2* decay we implemented an ultrashort echo-time sequence with a FLORET readout and estimated the temperature from the signal intensity. Results: Our method provided a good temperature accuracy combined with a high temporal resolution. Impact: During MR-guided cryoablation of tumors the proposed method could be used for therapy monitoring. It could thus enable a safer and more targeted way of destroying the tumor but not too much of the surrounding healthy tissue.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2192
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Temperature Mapping During MR-Guided Cryoablation Using a FLORET UTE Sequence

Frank Wacker, Bennet Hensen, Simon Schröer, Othmar Belker et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Heat Transfer and Boiling Studies
article

Temperature Mapping During MR-Guided Cryoablation Using a FLORET UTE Sequence

Frank Wacker, Bennet Hensen, Simon Schröer, Othmar Belker, Marcel Gutberlet, Moritz Gutt, Julienne Scheller
article en

Abstract

Motivation: Frozen tissue has a rapid T2* decay and low net magnetization. It thus appears as a signal void in most MR images. As tissue necrosis only happens between -20 and -40 °C it is not possible to distinguish between frozen and necrotic tissue during MR-guided cryoablation. Goal(s): Our goal was to estimate temperatures in frozen tissue. Approach: To encounter the rapid T2* decay we implemented an ultrashort echo-time sequence with a FLORET readout and estimated the temperature from the signal intensity. Results: Our method provided a good temperature accuracy combined with a high temporal resolution. Impact: During MR-guided cryoablation of tumors the proposed method could be used for therapy monitoring. It could thus enable a safer and more targeted way of destroying the tumor but not too much of the surrounding healthy tissue.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 75%
Heat Transfer and Boiling Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Temperature Mapping During MR-Guided Cryoablation Using a FLORET UTE Sequence — Frank Wacker, Bennet Hensen, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2025) | TGRS Research Map | TGRS