Assessing the Feasibility of PROPELLER DWI for Prostate Imaging in Patients with Metal Implants

Motivation: Propeller-DWI could reduce significant image distortion from metal implants. Goal(s): This study aims to investigate the improvement of image quality and the feasibility of ADC values in PROPELLER DWI for prostate with metal implants. Approach: We collected DWI images from 88 male participants. Our results showed the reduced distortion in the PROPELLER-DWI images, along with a strong liner correlation of ADC values between two DWI methods. Results: Based on the lesion detection rate of mean ADC values, the optimal cut-off ADC value for PROPELLER-DWI in tumor and lesion diagnosis should be set higher (1400x10-6mm2/s) than the cut-off ADC value for clinical EPI-DWI (930x10-6mm2/s). Impact: This study indicates reduced distortion of tissues near metal implants in PROPELLER-DWI and a strong linear correlation of ADC values between PROPELLER-DWI and EPI-DWI, suggesting PROPELLER-DWI would be valuable for the diagnosis of prostate cancer in patients with metal implants.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2279
Primary Topic
Welding Techniques and Residual Stresses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the Feasibility of PROPELLER DWI for Prostate Imaging in Patients with Metal Implants

Chia‐Wei Lee, Charng-Chyi Shieh, Yeun‐Chung Chang, Kao‐Lang Liu et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Welding Techniques and Residual Stresses
article

Assessing the Feasibility of PROPELLER DWI for Prostate Imaging in Patients with Metal Implants

Chia‐Wei Lee, Charng-Chyi Shieh, Yeun‐Chung Chang, Kao‐Lang Liu, Yi-Chen Chen, Chien‐Yuan Lin, Yu‐Ching Chen, Cheng-Ya Yeh
article en

Abstract

Motivation: Propeller-DWI could reduce significant image distortion from metal implants. Goal(s): This study aims to investigate the improvement of image quality and the feasibility of ADC values in PROPELLER DWI for prostate with metal implants. Approach: We collected DWI images from 88 male participants. Our results showed the reduced distortion in the PROPELLER-DWI images, along with a strong liner correlation of ADC values between two DWI methods. Results: Based on the lesion detection rate of mean ADC values, the optimal cut-off ADC value for PROPELLER-DWI in tumor and lesion diagnosis should be set higher (1400x10-6mm2/s) than the cut-off ADC value for clinical EPI-DWI (930x10-6mm2/s). Impact: This study indicates reduced distortion of tissues near metal implants in PROPELLER-DWI and a strong linear correlation of ADC values between PROPELLER-DWI and EPI-DWI, suggesting PROPELLER-DWI would be valuable for the diagnosis of prostate cancer in patients with metal implants.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 75%
Welding Techniques and Residual Stresses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.