Reproducibility of HERMES-measured GABA+ and GSH in the Mesial Temporal Lobe

Motivation: Quantification of measurement reproducibility of in vivo MRS experiments enables the planning of future studies. Evidence of reproducibility of simultaneous measurement of GABA and GSH using Hadamard-encoded spectral editing (i.e., HERMES) in challenging brain regions for MRS, such as the mesial temporal lobe (MTL), is needed. Goal(s): Determine the reproducibility of HERMES-sLASER in the MTL. Approach: Two MTL HERMES scans were acquired in 15 participants, with participants repositioned between scans. Results: The average CV for GABA+ was 14.09% and the average CV for GSH was 18.94%, comparable to previous work investigating these metabolites in the MTL using standalone acquisitions. Impact: This study quantifies the reproducibility of HERMES-sLASER in the challenging region of the mesial temporal lobe. These results show that this technique can be used to measure multiple metabolites by editing them simultaneously and provides guidance on expected effect sizes.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2919
Primary Topic
Neuroscience of respiration and sleep
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reproducibility of HERMES-measured GABA+ and GSH in the Mesial Temporal Lobe

Antis G. George, Paolo Federico, Marilena DeMayo, Victoria Mosher et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Neuroscience of respiration and sleep
article

Reproducibility of HERMES-measured GABA+ and GSH in the Mesial Temporal Lobe

Antis G. George, Paolo Federico, Marilena DeMayo, Victoria Mosher, Tiffany Bell, Mark E. Mikkelsen, Ashley Harris, Mary Botros
article en

Abstract

Motivation: Quantification of measurement reproducibility of in vivo MRS experiments enables the planning of future studies. Evidence of reproducibility of simultaneous measurement of GABA and GSH using Hadamard-encoded spectral editing (i.e., HERMES) in challenging brain regions for MRS, such as the mesial temporal lobe (MTL), is needed. Goal(s): Determine the reproducibility of HERMES-sLASER in the MTL. Approach: Two MTL HERMES scans were acquired in 15 participants, with participants repositioned between scans. Results: The average CV for GABA+ was 14.09% and the average CV for GSH was 18.94%, comparable to previous work investigating these metabolites in the MTL using standalone acquisitions. Impact: This study quantifies the reproducibility of HERMES-sLASER in the challenging region of the mesial temporal lobe. These results show that this technique can be used to measure multiple metabolites by editing them simultaneously and provides guidance on expected effect sizes.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 73%
Neuroscience of respiration and sleep
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.