Design of Shim Coil Arrays for Improving B0 Homogeneity in Brachial Plexus MRI at 3T

Motivation: Brachial plexus MRI at 3T is challenged by complex B0 inhomogeneities in the neck-shoulder region. Various body shapes and sizes in the population require research efforts to obtain those field distributions and design advanced shim coil arrays with body conditions similar to patients. Goal(s): Design shim coil arrays to minimize B0 inhomogeneities on the neck-shoulder. Approach: Numerical simulations of field distributions were performed based on whole-body CT images in a patient cohort. Multiple designs of shim coil arrays were tested on those field maps. Results: The simulation-derived optimal shim coil arrays substantially reduce B0 inhomogeneities on the neck-shoulder of in vivo-acquired field maps. Impact: B0-simulation-guided shim coil array design provides an efficient and economical way to derive optimized coil geometry that is applicable to patients with various body sizes and shapes, leading to a substantial reduction of B0 inhomogeneity for brachial plexus imaging.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2972
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of Shim Coil Arrays for Improving B0 Homogeneity in Brachial Plexus MRI at 3T

L. Wang, M. Binesh, Nader Binesh, Fardad Serry et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Design of Shim Coil Arrays for Improving B0 Homogeneity in Brachial Plexus MRI at 3T

L. Wang, M. Binesh, Nader Binesh, Fardad Serry, Jeremy Zepeda, Yun Shang, Ziyang Long, Xuanyu Zhu, Archana Malagi, Hsin-Jung Yang, Hui Han, Garima Diwan
article en

Abstract

Motivation: Brachial plexus MRI at 3T is challenged by complex B0 inhomogeneities in the neck-shoulder region. Various body shapes and sizes in the population require research efforts to obtain those field distributions and design advanced shim coil arrays with body conditions similar to patients. Goal(s): Design shim coil arrays to minimize B0 inhomogeneities on the neck-shoulder. Approach: Numerical simulations of field distributions were performed based on whole-body CT images in a patient cohort. Multiple designs of shim coil arrays were tested on those field maps. Results: The simulation-derived optimal shim coil arrays substantially reduce B0 inhomogeneities on the neck-shoulder of in vivo-acquired field maps. Impact: B0-simulation-guided shim coil array design provides an efficient and economical way to derive optimized coil geometry that is applicable to patients with various body sizes and shapes, leading to a substantial reduction of B0 inhomogeneity for brachial plexus imaging.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.