An Integrated 1H/2H Multichannel Head Coil for Improved Deuterium Metabolic Imaging

Motivation: To improve deuterium metabolic imaging (DMI) sensitivity at 3T. Goal(s): Characterize and test an 8Ch 1H / 16Ch 2H head coil. Approach: Deuterium (2H) CSI data were acquired with the 8Ch 1H / 16Ch 2H head coil and compared to a 1H/2H quadrature volume transceiver in one water phantom. DMI data were also acquired in one patient with glioblastoma after administering 2H-glucose. Results: SNR images demonstrated the deuterium 16Ch coil improves SNR by 2.5-fold at the periphery and 1.6-fold at the phantom center relative to 1H/2H quadrature coil. Glioma patient data demonstrated improved SNR, highlighting localized reduction in Glx and resolvable lactate signal. Impact: Improved SNR in 3T DMI with an integrated 1H/2H multichannel array coil has the potential to greatly improve the detection of impaired glucose metabolism and regional differences in brain disease diagnosis.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2906
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Integrated 1H/2H Multichannel Head Coil for Improved Deuterium Metabolic Imaging

David M. Wilson, Huilou Liang, Duan Xu, Annick Haller et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

An Integrated 1H/2H Multichannel Head Coil for Improved Deuterium Metabolic Imaging

David M. Wilson, Huilou Liang, Duan Xu, Annick Haller, Jeremy W. Gordon, Adam Autry, Yu Zhao, Christoffer Laustsen, Michael Væggemose, Chunsheng Wang, Yan Li, Lucas Carvajal
article en

Abstract

Motivation: To improve deuterium metabolic imaging (DMI) sensitivity at 3T. Goal(s): Characterize and test an 8Ch 1H / 16Ch 2H head coil. Approach: Deuterium (2H) CSI data were acquired with the 8Ch 1H / 16Ch 2H head coil and compared to a 1H/2H quadrature volume transceiver in one water phantom. DMI data were also acquired in one patient with glioblastoma after administering 2H-glucose. Results: SNR images demonstrated the deuterium 16Ch coil improves SNR by 2.5-fold at the periphery and 1.6-fold at the phantom center relative to 1H/2H quadrature coil. Glioma patient data demonstrated improved SNR, highlighting localized reduction in Glx and resolvable lactate signal. Impact: Improved SNR in 3T DMI with an integrated 1H/2H multichannel array coil has the potential to greatly improve the detection of impaired glucose metabolism and regional differences in brain disease diagnosis.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 65%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.