Phase-Based R2 Mapping for Single Breath-Hold Whole-Liver Iron Quantification : Clinical Validation

Motivation: Liver iron overload can cause serious complications; accurate assessment is essential. Current R2 mapping techniques are limited by long scan times and fat-induced bias. Goal(s): To validate a rapid phase-based (PB) R2 mapping method for whole-liver iron quantification by comparing it with conventional methods, and to understand fat bias through simulations. Approach: PB-R2 mapping using RF phase-modulated 3D GRE imaging was tested in patients with iron overload at 1.5T and 3.0T MRI. Results: PB-R2 mapping showed good agreement with reference methods over a wide range of iron concentrations and excellent repeatability. Impact: PB-R2 mapping enables rapid, accurate whole-liver iron quantification within a single breath-hold, enhancing clinical efficiency and patient comfort. It may improve iron overload assessment and inspire further research to address fat bias in R2 mapping.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2664
Primary Topic
Iron Metabolism and Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Phase-Based R2 Mapping for Single Breath-Hold Whole-Liver Iron Quantification : Clinical Validation

Ruvini Navaratna, Diego Hernando, Scott B. Reeder, Daiki Tamada et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Iron Metabolism and Disorders
article

Phase-Based R2 Mapping for Single Breath-Hold Whole-Liver Iron Quantification : Clinical Validation

Ruvini Navaratna, Diego Hernando, Scott B. Reeder, Daiki Tamada, Jayse Weaver
article en

Abstract

Motivation: Liver iron overload can cause serious complications; accurate assessment is essential. Current R2 mapping techniques are limited by long scan times and fat-induced bias. Goal(s): To validate a rapid phase-based (PB) R2 mapping method for whole-liver iron quantification by comparing it with conventional methods, and to understand fat bias through simulations. Approach: PB-R2 mapping using RF phase-modulated 3D GRE imaging was tested in patients with iron overload at 1.5T and 3.0T MRI. Results: PB-R2 mapping showed good agreement with reference methods over a wide range of iron concentrations and excellent repeatability. Impact: PB-R2 mapping enables rapid, accurate whole-liver iron quantification within a single breath-hold, enhancing clinical efficiency and patient comfort. It may improve iron overload assessment and inspire further research to address fat bias in R2 mapping.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 68%
Iron Metabolism and Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.