Comparative Analysis of Liver Iron Concentration: Inline R2* of mDixon-Quant and Multi-Echo Gradient Echo Versus Spin Echo Method

Motivation: FDA approved Ferriscan spin echo (SE) method for estimating liver iron concentration(LIC) suffers from significant motion artifact, report delay and cost from third party process. The accurate LIC, short processing time and good quality images were required from clinical practice. Goal(s): Testing agreement of LIC between the two product sequences versus LICSE Approach: Comparing LIC, from inline R2* maps using: 3D mDixon-quant(mDixon) and multi-echo gradient echo (mGRE), to LICSE in a large population (126 clinical subjects) Results: LICmGRE agrees more closely than LICmDixon to LICSE in normal to mild iron overload cases while LICmDixon outperforms LICmGRE in moderate to severe iron overload cases. Impact: The Liver Iron Concentration (LIC) calculated using the inline R2*maps from both 3D mDixon and multi-echo GRE methods (mGRE) (each with single breath-hold of <12s) strongly correlated to the FDA approved Ferriscan spin echo (SE) based method.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2025-09-16
DOI
https://doi.org/10.58530/2025/2663
Primary Topic
NMR spectroscopy and applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Analysis of Liver Iron Concentration: Inline R2* of mDixon-Quant and Multi-Echo Gradient Echo Versus Spin Echo Method

Naiim Ali, Jiming Zhang, Dmitriy Akselrod, Scott Hipko
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
NMR spectroscopy and applications
article

Comparative Analysis of Liver Iron Concentration: Inline R2* of mDixon-Quant and Multi-Echo Gradient Echo Versus Spin Echo Method

Naiim Ali, Jiming Zhang, Dmitriy Akselrod, Scott Hipko
article en

Abstract

Motivation: FDA approved Ferriscan spin echo (SE) method for estimating liver iron concentration(LIC) suffers from significant motion artifact, report delay and cost from third party process. The accurate LIC, short processing time and good quality images were required from clinical practice. Goal(s): Testing agreement of LIC between the two product sequences versus LICSE Approach: Comparing LIC, from inline R2* maps using: 3D mDixon-quant(mDixon) and multi-echo gradient echo (mGRE), to LICSE in a large population (126 clinical subjects) Results: LICmGRE agrees more closely than LICmDixon to LICSE in normal to mild iron overload cases while LICmDixon outperforms LICmGRE in moderate to severe iron overload cases. Impact: The Liver Iron Concentration (LIC) calculated using the inline R2*maps from both 3D mDixon and multi-echo GRE methods (mGRE) (each with single breath-hold of <12s) strongly correlated to the FDA approved Ferriscan spin echo (SE) based method.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 90%
NMR spectroscopy and applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.