Brightness mode (B-mode) ultrasound is a popular, non-invasive imaging modality used to assess skeletal muscle size. While popular, it is paramount for accuracy and reliability that these images are acquired by a trained and experienced technician. Otherwise, it is difficult to obtain high-quality and repeatable scans. A recent custom-built ultrasound probe guide (PGT) has recently been developed, which may reduce measurement error and increase the reliability of ultrasound imaging. PURPOSE: The purpose of this study was to assess the test-retest reliability between the PGT and traditional (TRAD) ultrasound imaging for the measurement of muscle volume of the vastus lateralis (VL). METHODS: 40 participants (mean ± SD: age = 21 ± 3 yrs; BMI = 24.5 ± 4.2 kg/m2) completed one visit to the laboratory where each participant underwent non-invasive B-mode imaging on their VL across four separate image acquisition sessions, each separated by 10 minutes. Two trials utilized the PGT while the other two trials used the TRAD method. The PGT consisted of a customized cradle which was 3D printed to fit the exact dimensions of the ultrasound probe used in this study. To acquire images, the cradle, which controlled the pitch and yaw of the probe, was then placed on custom-designed tracks on which it glided during a cross-sectional plane ultrasound scan. Anatomical cross-sectional area (ACSA) was quantified every 1.5 cm along the length of the VL, which was standardized based on the capabilities of the PGT. During the two TRAD trials, scans occurred in the same locations as the PGT trials. Muscle volume was estimated using the Cavalieri technique with the ACSA scans. Test-retest reliability statistics (i.e., interclass correlation coefficients [ICC] model 2,1, standard error of measurement as a percentage of the mean [SEM], and the minimal difference [MD] values needed to be considered real) were quantified. RESULTS: Both the PGT method (ICC2,1 = 0.96, SEM = 3.56%, MD = 6.98 cm3) and TRAD (ICC2,1 = 0.98, SEM = 2.41%, MD = 4.73 cm3) demonstrated good reliability. CONCLUSIONS: The findings from the present investigation suggest that the TRAD and PGT have excellent reliability when used to quantify VL muscle volume, but the TRAD may have less error and variability between scans compared to PGT.

Authors

Institutions

Publication Details

Journal
Medicine & Science in Sports & Exercise
Published
2025-09-16
DOI
https://doi.org/10.1249/01.mss.0001154980.57164.1d
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Test-retest Reliability Of An Ultrasound Probe Guide System

Grant M. Tinsley, Malia N.M. Blue, Kealey J. Wohlgemuth, Carina M. Velasquez et al.
Medicine & Science in Sports & Exercise
Engineering Applied Research
article

Test-retest Reliability Of An Ultrasound Probe Guide System

Grant M. Tinsley, Malia N.M. Blue, Kealey J. Wohlgemuth, Carina M. Velasquez, Jacob A. Mota
article en

Abstract

Brightness mode (B-mode) ultrasound is a popular, non-invasive imaging modality used to assess skeletal muscle size. While popular, it is paramount for accuracy and reliability that these images are acquired by a trained and experienced technician. Otherwise, it is difficult to obtain high-quality and repeatable scans. A recent custom-built ultrasound probe guide (PGT) has recently been developed, which may reduce measurement error and increase the reliability of ultrasound imaging. PURPOSE: The purpose of this study was to assess the test-retest reliability between the PGT and traditional (TRAD) ultrasound imaging for the measurement of muscle volume of the vastus lateralis (VL). METHODS: 40 participants (mean ± SD: age = 21 ± 3 yrs; BMI = 24.5 ± 4.2 kg/m2) completed one visit to the laboratory where each participant underwent non-invasive B-mode imaging on their VL across four separate image acquisition sessions, each separated by 10 minutes. Two trials utilized the PGT while the other two trials used the TRAD method. The PGT consisted of a customized cradle which was 3D printed to fit the exact dimensions of the ultrasound probe used in this study. To acquire images, the cradle, which controlled the pitch and yaw of the probe, was then placed on custom-designed tracks on which it glided during a cross-sectional plane ultrasound scan. Anatomical cross-sectional area (ACSA) was quantified every 1.5 cm along the length of the VL, which was standardized based on the capabilities of the PGT. During the two TRAD trials, scans occurred in the same locations as the PGT trials. Muscle volume was estimated using the Cavalieri technique with the ACSA scans. Test-retest reliability statistics (i.e., interclass correlation coefficients [ICC] model 2,1, standard error of measurement as a percentage of the mean [SEM], and the minimal difference [MD] values needed to be considered real) were quantified. RESULTS: Both the PGT method (ICC2,1 = 0.96, SEM = 3.56%, MD = 6.98 cm3) and TRAD (ICC2,1 = 0.98, SEM = 2.41%, MD = 4.73 cm3) demonstrated good reliability. CONCLUSIONS: The findings from the present investigation suggest that the TRAD and PGT have excellent reliability when used to quantify VL muscle volume, but the TRAD may have less error and variability between scans compared to PGT.

Medicine & Science in Sports & ExerciseVol. 57(10S)
University of North Carolina at Chapel Hill (US), Texas Tech University (US)
Openalex Percentile: Top 74%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.