Hip And Wrist Accelerometer Cut-points For Adults With Down Syndrome

Adults with Down syndrome (DS) have very low aerobic fitness. Accelerometer cut-points for moderate and vigorous physical activity (PA) may thus be more appropriate if developed based on the oxygen uptake reserve (%VO2R) which accounts for aerobic fitness. PURPOSE: To develop cut-points for moderate and vigorous PA for adults with DS based on %VO2R from hip and wrist accelerometer output. METHODS: Forty-one adults with DS (19 women; age 35 ± 9 years) performed 17 tasks for 6 min each: sitting; standing; walking over-ground at 3 speeds; running; watching movie; playing app; drawing; folding clothes; vacuuming; sweeping; moving a box; basketball; soccer; fitness circuit; and dancing. Aerobic fitness was estimated with a submaximal treadmill test. Oxygen uptake was measured with breath-by-breath open-circuit spirometry (K5, Cosmed) and expressed as %VO2R. Output from hip and wrist accelerometers (wGT3X-BT, Actigraph) was determined as Vector Magnitude (VM). VM cut-points for moderate and vigorous PA were identified with Receiver Operating Characteristic (ROC) curves based on %VO2R of 40.0 - 59.9% and ≥ 60%, respectively. Optimal cut-points for moderate and vigorous PA that maximized sensitivity, specificity and Youden’s index (YI) were selected. RESULTS: Area Under the ROC Curve (AUC) and Gini Index (GI) were high for all models; for the hip accelerometer: (a) moderate intensity PA (AUC 0.87 95% CI: 0.85 - 0.90; GI 0.74;) and (b) vigorous intensity PA (AUC 0.86; 95% CI: 0.83 - 0.90; GI 0.72;); and for the wrist accelerometer: (a) moderate intensity PA (AUC 0.84; 95% CI: 0.81 - 0.86; GI 0.67;) and (b) vigorous intensity PA (AUC 0.85; 95% CI: 0.81 - 0.88; GI 0.70). The optimal VM cut-points for the hip accelerometer were: (a) moderate PA ≥2065 counts·min-1 (sensitivity 0.97; specificity 0.70; YI 0.66); and (b) vigorous PA ≥3353 counts·min-1 (sensitivity 0.85; specificity 0.72; YI 0.57). VM cut-points based on the wrist accelerometer were: (a) moderate PA ≥3803 counts·min-1 (sensitivity 0.87; specificity 0.66; YI 0.53); and (b) vigorous PA ≥6639 counts·min-1 (sensitivity 0.72; specificity 0.80; YI 0.52). CONCLUSION: Hip and wrist accelerometer cut-points for PA intensity based on %VO2R appear accurate and, if utilized, may improve PA assessment in adults with DS. Funding: NIH R15HD098660 Supported by: NIH R15HD098660

Authors

Institutions

Publication Details

Journal
Medicine & Science in Sports & Exercise
Published
2025-09-16
DOI
https://doi.org/10.1249/01.mss.0001160172.81927.aa
Primary Topic
Quality and Safety in Healthcare
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hip And Wrist Accelerometer Cut-points For Adults With Down Syndrome

Stamatis Agiovlasitis, Maria Haider, Brantley K. Ballenger, Robert W. Motl et al.
Medicine & Science in Sports & Exercise
Quality and Safety in Healthcare
article

Hip And Wrist Accelerometer Cut-points For Adults With Down Syndrome

Stamatis Agiovlasitis, Maria Haider, Brantley K. Ballenger, Robert W. Motl, Poram Choi, G. H. Starr
article en

Abstract

Adults with Down syndrome (DS) have very low aerobic fitness. Accelerometer cut-points for moderate and vigorous physical activity (PA) may thus be more appropriate if developed based on the oxygen uptake reserve (%VO2R) which accounts for aerobic fitness. PURPOSE: To develop cut-points for moderate and vigorous PA for adults with DS based on %VO2R from hip and wrist accelerometer output. METHODS: Forty-one adults with DS (19 women; age 35 ± 9 years) performed 17 tasks for 6 min each: sitting; standing; walking over-ground at 3 speeds; running; watching movie; playing app; drawing; folding clothes; vacuuming; sweeping; moving a box; basketball; soccer; fitness circuit; and dancing. Aerobic fitness was estimated with a submaximal treadmill test. Oxygen uptake was measured with breath-by-breath open-circuit spirometry (K5, Cosmed) and expressed as %VO2R. Output from hip and wrist accelerometers (wGT3X-BT, Actigraph) was determined as Vector Magnitude (VM). VM cut-points for moderate and vigorous PA were identified with Receiver Operating Characteristic (ROC) curves based on %VO2R of 40.0 - 59.9% and ≥ 60%, respectively. Optimal cut-points for moderate and vigorous PA that maximized sensitivity, specificity and Youden’s index (YI) were selected. RESULTS: Area Under the ROC Curve (AUC) and Gini Index (GI) were high for all models; for the hip accelerometer: (a) moderate intensity PA (AUC 0.87 95% CI: 0.85 - 0.90; GI 0.74;) and (b) vigorous intensity PA (AUC 0.86; 95% CI: 0.83 - 0.90; GI 0.72;); and for the wrist accelerometer: (a) moderate intensity PA (AUC 0.84; 95% CI: 0.81 - 0.86; GI 0.67;) and (b) vigorous intensity PA (AUC 0.85; 95% CI: 0.81 - 0.88; GI 0.70). The optimal VM cut-points for the hip accelerometer were: (a) moderate PA ≥2065 counts·min-1 (sensitivity 0.97; specificity 0.70; YI 0.66); and (b) vigorous PA ≥3353 counts·min-1 (sensitivity 0.85; specificity 0.72; YI 0.57). VM cut-points based on the wrist accelerometer were: (a) moderate PA ≥3803 counts·min-1 (sensitivity 0.87; specificity 0.66; YI 0.53); and (b) vigorous PA ≥6639 counts·min-1 (sensitivity 0.72; specificity 0.80; YI 0.52). CONCLUSION: Hip and wrist accelerometer cut-points for PA intensity based on %VO2R appear accurate and, if utilized, may improve PA assessment in adults with DS. Funding: NIH R15HD098660 Supported by: NIH R15HD098660

Medicine & Science in Sports & ExerciseVol. 57(10S)
Sonoma State University (US), University of Illinois Chicago (US), Transylvania University (US), Mississippi State University (US)
Openalex Percentile: Top 54%
Quality and Safety in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.