Improved Approach for Intima-Media Thickness Measurement in Carotid Ultrasound Imaging Using Adaptive Despeckle Filtering

This paper addresses the challenge of Intima-Media Thickness (IMT) measurement, a critical technique for assessing cardiovascular risk, by focusing on the impact of speckle noise in ultrasound (US) imaging. The presence of speckle noise degrades the accuracy of IMT measurements, making effective despeckling essential. However, there is a trade-off between noise reduction, surface smoothing, and structural preservation. This study proposes the efficiency of despeckling filters in improving IMT measurement accuracy. The effectiveness of speckle suppression is quantified using the Normalized Mean Square Error (NMSE), while visual quality is assessed through Peak Signal-to-Noise Ratio (PSNR). Structural preservation post-filtering is evaluated using the Mean Structural Similarity Index (MSSIM). Furthermore, IMT detection accuracy is measured using the Mean Absolute Distance (MAD), representing IMT error. The study presents the Adaptive Regularization Savitzky-Golay (ARSG) filter as the best-performing method. It shows that the ARSG filter reduces IMT measurement error (with a MAD of 9.54) and achieves a high level of structural preservation (with an MSSIM of 89.39%). Compared to other methods, the ARSG filter provides a better balance between noise reduction and structural integrity, leading to improved IMT measurement accuracy. In summary, the paper demonstrates that the ARSG filter is highly IMT measurements by balancing noise suppression and the preservation of image structure, making it a valuable tool for assessing cardiovascular risk through ultrasound imaging.

Authors

Institutions

Publication Details

Published
2025-07-19
DOI
https://doi.org/10.1109/amlds63918.2025.11159368
Primary Topic
Cardiovascular Health and Disease Prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Approach for Intima-Media Thickness Measurement in Carotid Ultrasound Imaging Using Adaptive Despeckle Filtering

Vera Sa‐ing, Pongpat Vorasayan, Supatana Auethavekiat, Wilaiporn Lee et al.
Cardiovascular Health and Disease Prevention
article

Improved Approach for Intima-Media Thickness Measurement in Carotid Ultrasound Imaging Using Adaptive Despeckle Filtering

Vera Sa‐ing, Pongpat Vorasayan, Supatana Auethavekiat, Wilaiporn Lee, C. Chinrungrueng, Kanabadee Srisomboon
article en

Abstract

This paper addresses the challenge of Intima-Media Thickness (IMT) measurement, a critical technique for assessing cardiovascular risk, by focusing on the impact of speckle noise in ultrasound (US) imaging. The presence of speckle noise degrades the accuracy of IMT measurements, making effective despeckling essential. However, there is a trade-off between noise reduction, surface smoothing, and structural preservation. This study proposes the efficiency of despeckling filters in improving IMT measurement accuracy. The effectiveness of speckle suppression is quantified using the Normalized Mean Square Error (NMSE), while visual quality is assessed through Peak Signal-to-Noise Ratio (PSNR). Structural preservation post-filtering is evaluated using the Mean Structural Similarity Index (MSSIM). Furthermore, IMT detection accuracy is measured using the Mean Absolute Distance (MAD), representing IMT error. The study presents the Adaptive Regularization Savitzky-Golay (ARSG) filter as the best-performing method. It shows that the ARSG filter reduces IMT measurement error (with a MAD of 9.54) and achieves a high level of structural preservation (with an MSSIM of 89.39%). Compared to other methods, the ARSG filter provides a better balance between noise reduction and structural integrity, leading to improved IMT measurement accuracy. In summary, the paper demonstrates that the ARSG filter is highly IMT measurements by balancing noise suppression and the preservation of image structure, making it a valuable tool for assessing cardiovascular risk through ultrasound imaging.

Chulalongkorn University (TH), King Chulalongkorn Memorial Hospital (TH), King Mongkut's University of Technology North Bangkok (TH)
Openalex Percentile: Top 62%
Cardiovascular Health and Disease Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.