A Modified Ellipsoid Calibration Method for Three-Axis Magnetometer Based on Anisotropic Magnetoresistive Sensors

Calibration is essential to three-axis magnetometers in most applications. Typically, ellipsoid calibration method considers a sensor’s positive sensitive directions along its geometric axes as default, which may lead to inaccurate in sensitivities and misalignments. In this work, we propose a modified ellipsoid calibration algorithm to eliminate such indeterminacy. A three-axis magnetometer comprised of anisotropic magnetoresistive sensors and 3D printed structure was calibrated to prove the effectiveness of proposed method. And it realized 1.68° and 3.94° average errors of azimuth and elevation, respectively, for spatial DC magnetic field angle detection. Also, we demonstrate a two-step method for angle resolving, and a Monte Carlo simulation method for calibration performance prediction based on uncertainties. The proposed method reveals significant potential for calibration and evaluation of three-axis magnetometers.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Magnetics
Published
2025-09-16
DOI
https://doi.org/10.1109/tmag.2025.3610542
Primary Topic
Inertial Sensor and Navigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Modified Ellipsoid Calibration Method for Three-Axis Magnetometer Based on Anisotropic Magnetoresistive Sensors

Jingen Wu, Yongjun Du, Jiacheng Qiao, Fuzhe Fan et al.
IEEE Transactions on Magnetics
Inertial Sensor and Navigation
article

A Modified Ellipsoid Calibration Method for Three-Axis Magnetometer Based on Anisotropic Magnetoresistive Sensors

Jingen Wu, Yongjun Du, Jiacheng Qiao, Fuzhe Fan, Zhongqiang Hu, Ming Liu, Yang Li, Zhiguang Wang, Yiwei Xu, Heng Huang
article en

Abstract

Calibration is essential to three-axis magnetometers in most applications. Typically, ellipsoid calibration method considers a sensor’s positive sensitive directions along its geometric axes as default, which may lead to inaccurate in sensitivities and misalignments. In this work, we propose a modified ellipsoid calibration algorithm to eliminate such indeterminacy. A three-axis magnetometer comprised of anisotropic magnetoresistive sensors and 3D printed structure was calibrated to prove the effectiveness of proposed method. And it realized 1.68° and 3.94° average errors of azimuth and elevation, respectively, for spatial DC magnetic field angle detection. Also, we demonstrate a two-step method for angle resolving, and a Monte Carlo simulation method for calibration performance prediction based on uncertainties. The proposed method reveals significant potential for calibration and evaluation of three-axis magnetometers.

IEEE Transactions on MagneticsVol. 61(11)
Xi'an Jiaotong University (CN)
Openalex Percentile: Top 67%
Inertial Sensor and Navigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.