Integrated Fault Diagnosis Method for IGBT Open Circuit Fault and Voltage Sensor Fault in MMC Submodule

The MMC system contains numerous submodules. The frequent occurrence of switch open-circuit fault and submodule voltage sensor faults have similar fault characteristics, leads to degraded system reliability. This paper proposes an integrated diagnosis method for submodule IGBT open-circuit faults and voltage sensor faults based on a sliding mode observer. Firstly, the fault detection variable is designed based on the actual bridge arm voltage values and the measured bridge arm voltage values to detect the occurrence of fault and to locate it to the bridge arm level. Then, for each submodule of the faulty bridge arm, a sliding mode observer is designed to estimate the submodule capacitor voltage value, which is compared with the measured value to further locate the fault to a specific submodule. Finally, the submodule capacitor voltage information is utilized to distinguish between specific IGBT upper and lower open-circuit faults and three typical fault types of voltage sensors. The effectiveness and robustness of the proposed fault diagnosis algorithm are validated through hardware-in-loop simulation results.

Authors

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3610632
Citations
1
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrated Fault Diagnosis Method for IGBT Open Circuit Fault and Voltage Sensor Fault in MMC Submodule

Yang Chen, Xu Yang, Ke Zhao, Tianxi Xie et al.
1 citations
IEEE Access
High-Voltage Power Transmission Systems
0.73
article

Integrated Fault Diagnosis Method for IGBT Open Circuit Fault and Voltage Sensor Fault in MMC Submodule

Yang Chen, Xu Yang, Ke Zhao, Tianxi Xie, Jinggang Yang, Xuan Feng
article en
1 citations

Abstract

The MMC system contains numerous submodules. The frequent occurrence of switch open-circuit fault and submodule voltage sensor faults have similar fault characteristics, leads to degraded system reliability. This paper proposes an integrated diagnosis method for submodule IGBT open-circuit faults and voltage sensor faults based on a sliding mode observer. Firstly, the fault detection variable is designed based on the actual bridge arm voltage values and the measured bridge arm voltage values to detect the occurrence of fault and to locate it to the bridge arm level. Then, for each submodule of the faulty bridge arm, a sliding mode observer is designed to estimate the submodule capacitor voltage value, which is compared with the measured value to further locate the fault to a specific submodule. Finally, the submodule capacitor voltage information is utilized to distinguish between specific IGBT upper and lower open-circuit faults and three typical fault types of voltage sensors. The effectiveness and robustness of the proposed fault diagnosis algorithm are validated through hardware-in-loop simulation results.

IEEE AccessVol. 13
Openalex Percentile: Top 23%
High-Voltage Power Transmission Systems
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.