An ECG Monitoring System Using SAR ADC on Flexible Foil With Oxide TFT Technology

This manuscript presents an electrocardiogram (ECG) monitoring system with charge redistribution noise shaping successive approximation register analog to digital converter (CR-NS SAR ADC). The proposed system has successfully demonstrated an ECG reconstruction while preserving crucial parameters such as PR, QT, ST, QRS, RR interval, and heart rate, which are essential for analyzing ECG data. The ADC is designed using single-gate Indium-Gallium-Zinc-Oxide thin-film transistor (IGZO TFT) technology only with n-type TFTs and fabricated on a 30 μm thick polyimide substrate. Further, this work has addressed circuit design challenges that arise due to only n-type transistor based implementation. This ADC employs an energy efficient modified CR switching scheme, which utilizes merged capacitor switching (MCS) technique. Moreover, for the first time, first-order passive NS technique is experimented with this technology in the ADC. From measurements, this circuit shows a walden figure-of-merit (<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">FoM<sub>W</sub></i>) of 13.8 nJ/c.s, schreier FoM (<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">FoM<sub>S</sub></i>) of 98.298 dB, SNR of 39.23 dB and ENOB of 6-bits. The proposed ADC operates up to a sampling frequency of 2.08 kHz with a power consumption of 1.85mW at a supply voltage (<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">V<sub>DD</sub></i>) of 4V. This design is well suited for biomedical wearable devices because of its low-power operation and compatibility with flexible substrates.

Authors

Institutions

Publication Details

Journal
IEEE Journal on Flexible Electronics
Published
2025-09-16
DOI
https://doi.org/10.1109/jflex.2025.3610362
Primary Topic
CCD and CMOS Imaging Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An ECG Monitoring System Using SAR ADC on Flexible Foil With Oxide TFT Technology

Suyash Shrivastava, Vaishali Choudhary, Pydi Ganga Bahubalindruni, Bhawna Tiwari
IEEE Journal on Flexible Electronics
CCD and CMOS Imaging Sensors
article

An ECG Monitoring System Using SAR ADC on Flexible Foil With Oxide TFT Technology

Suyash Shrivastava, Vaishali Choudhary, Pydi Ganga Bahubalindruni, Bhawna Tiwari
article en

Abstract

This manuscript presents an electrocardiogram (ECG) monitoring system with charge redistribution noise shaping successive approximation register analog to digital converter (CR-NS SAR ADC). The proposed system has successfully demonstrated an ECG reconstruction while preserving crucial parameters such as PR, QT, ST, QRS, RR interval, and heart rate, which are essential for analyzing ECG data. The ADC is designed using single-gate Indium-Gallium-Zinc-Oxide thin-film transistor (IGZO TFT) technology only with n-type TFTs and fabricated on a 30 μm thick polyimide substrate. Further, this work has addressed circuit design challenges that arise due to only n-type transistor based implementation. This ADC employs an energy efficient modified CR switching scheme, which utilizes merged capacitor switching (MCS) technique. Moreover, for the first time, first-order passive NS technique is experimented with this technology in the ADC. From measurements, this circuit shows a walden figure-of-merit (<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">FoM<sub>W</sub></i>) of 13.8 nJ/c.s, schreier FoM (<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">FoM<sub>S</sub></i>) of 98.298 dB, SNR of 39.23 dB and ENOB of 6-bits. The proposed ADC operates up to a sampling frequency of 2.08 kHz with a power consumption of 1.85mW at a supply voltage (<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">V<sub>DD</sub></i>) of 4V. This design is well suited for biomedical wearable devices because of its low-power operation and compatibility with flexible substrates.

IEEE Journal on Flexible ElectronicsVol. 4(10)
Indian Institute of Science Education and Research, Bhopal (IN)
Openalex Percentile: Top 76%
CCD and CMOS Imaging Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.