Capillary Soil Nutrient Profiling Device: Pre-Processing Free Approach for Rapid Soil Nutrient Assessment

The development of reliable point-of-source devices for soil nutrient profiling holds the key to unlocking maximum agricultural output while promoting sustainable practices with minimal environmental impact. The dynamic nature of the soil, its testing protocols, and multistep pre-processing of samples results in time-dependent responses from the sensors increasing the testing time and cost requires additional peripheral equipment. Thus, portability along with precision gets affected simultaneously. Moreover, signal processing, data generation, and acquisition also compromise the soil nutrient assessment. In this work, a standalone device was developed with an alternate soil nutrient quantification protocol for nitrate and potassium, leveraging the capillary forces in the cellulose substrate owed to porous architecture and inter-cellulose fiber voids to eliminate conventional protocols like extraction, centrifugation, and filtration (to eliminate matrix effects) to achieve single-step soil nutrient quantification. Additionally, the use of external 24-bit analog-to-digital conversion (ADC), a quick 2-point calibration smartphone was employed to increase the resolution of the measurements and accuracy of the nutrient measurements. Compared to traditional soil testing methods, the proposed system demonstrated a detection limit and quantization limit of 0.1 mM, with a linear response range of 0.5-21 mM for potassium and 0.2-1.4 mM for nitrate. Precision tests across 15 reuse cycles showed average variability below ±5%, confirming the reliability and repeatability of the sensor. The proposed approach can have broader implications such as the development of portable, low-cost, processing-free, and reliable soil nutrient sensors for in-field applications.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on NanoBioscience
Published
2025-09-16
DOI
https://doi.org/10.1109/tnb.2025.3610506
Primary Topic
Water Quality Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Capillary Soil Nutrient Profiling Device: Pre-Processing Free Approach for Rapid Soil Nutrient Assessment

Abhishesh Pal, K.S. Deepak, Sanket Goel, Satish Kumar Dubey et al.
IEEE Transactions on NanoBioscience
Water Quality Monitoring and Analysis
article

Capillary Soil Nutrient Profiling Device: Pre-Processing Free Approach for Rapid Soil Nutrient Assessment

Abhishesh Pal, K.S. Deepak, Sanket Goel, Satish Kumar Dubey, Prasanta K. Kalita
article en

Abstract

The development of reliable point-of-source devices for soil nutrient profiling holds the key to unlocking maximum agricultural output while promoting sustainable practices with minimal environmental impact. The dynamic nature of the soil, its testing protocols, and multistep pre-processing of samples results in time-dependent responses from the sensors increasing the testing time and cost requires additional peripheral equipment. Thus, portability along with precision gets affected simultaneously. Moreover, signal processing, data generation, and acquisition also compromise the soil nutrient assessment. In this work, a standalone device was developed with an alternate soil nutrient quantification protocol for nitrate and potassium, leveraging the capillary forces in the cellulose substrate owed to porous architecture and inter-cellulose fiber voids to eliminate conventional protocols like extraction, centrifugation, and filtration (to eliminate matrix effects) to achieve single-step soil nutrient quantification. Additionally, the use of external 24-bit analog-to-digital conversion (ADC), a quick 2-point calibration smartphone was employed to increase the resolution of the measurements and accuracy of the nutrient measurements. Compared to traditional soil testing methods, the proposed system demonstrated a detection limit and quantization limit of 0.1 mM, with a linear response range of 0.5-21 mM for potassium and 0.2-1.4 mM for nitrate. Precision tests across 15 reuse cycles showed average variability below ±5%, confirming the reliability and repeatability of the sensor. The proposed approach can have broader implications such as the development of portable, low-cost, processing-free, and reliable soil nutrient sensors for in-field applications.

IEEE Transactions on NanoBioscienceVol. 25(1)
University of Illinois Urbana-Champaign (US), Birla Institute of Technology and Science - Hyderabad Campus (IN)
Openalex Percentile: Top 70%
Water Quality Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.