Fault Detection and Response for Safe Control of Artificial Muscles in Soft Robots

Robots built from soft materials have the potential for intuitively-safer interactions with humans and the environment. However, soft robots’ embodiments have many sources of failure that could lead to unsafe conditions in closed-loop control, such as degradation of sensors or fracture of actuators. This article proposes a fault detection system for sensors attached to artificial muscle actuators that satisfies a formal safety condition. Our approach combines redundant sensing, model-based state estimation, and Gaussian process regression to determine when one sensor’s reading statistically diverges from another, indicating a fault condition. We apply the approach to electrothermal shape memory alloy (SMA) artificial muscles, demonstrating that our method prevents the overheating and fire damage risk that could otherwise occur. Experiments show that when the muscle’s nominal sensor (temperature via a thermocouple) is fractured from the robot, the redundant sensor (electrical resistance) combined with our method prevents violation of state constraints. Deploying this system in real-world human-robot interaction could help make soft robots more robust and reliable.

Authors

Institutions

Publication Details

Journal
IEEE Control Systems Letters
Published
2025-01-01
DOI
https://doi.org/10.1109/lcsys.2025.3610637
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault Detection and Response for Safe Control of Artificial Muscles in Soft Robots

Andrew P. Sabelhaus, Ran Jing, Ilyoung Yang, Charles Van Hook
IEEE Control Systems Letters
Advanced Sensor and Energy Harvesting Materials
article

Fault Detection and Response for Safe Control of Artificial Muscles in Soft Robots

Andrew P. Sabelhaus, Ran Jing, Ilyoung Yang, Charles Van Hook
article en

Abstract

Robots built from soft materials have the potential for intuitively-safer interactions with humans and the environment. However, soft robots’ embodiments have many sources of failure that could lead to unsafe conditions in closed-loop control, such as degradation of sensors or fracture of actuators. This article proposes a fault detection system for sensors attached to artificial muscle actuators that satisfies a formal safety condition. Our approach combines redundant sensing, model-based state estimation, and Gaussian process regression to determine when one sensor’s reading statistically diverges from another, indicating a fault condition. We apply the approach to electrothermal shape memory alloy (SMA) artificial muscles, demonstrating that our method prevents the overheating and fire damage risk that could otherwise occur. Experiments show that when the muscle’s nominal sensor (temperature via a thermocouple) is fractured from the robot, the redundant sensor (electrical resistance) combined with our method prevents violation of state constraints. Deploying this system in real-world human-robot interaction could help make soft robots more robust and reliable.

IEEE Control Systems LettersVol. 9
Boston University (US)
Openalex Percentile: Top 76%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fault Detection and Response for Safe Control of Artificial Muscles in Soft Robots — Andrew P. Sabelhaus, Ran Jing, et al. · IEEE Control Systems Letters (2025) | TGRS Research Map | TGRS