Novel multi-scan-body cone-beam CT: comparison with photon-counting and energy-integrating CT in an anthropomorphic hand phantom

BackgroundCone-beam computed tomography (CBCT) can offer advantages over multidetector CT in dose efficiency and economic costs, but musculoskeletal applications were limited in gantry-free systems.PurposeTo assess the utility of novel multi-scan-body CBCT for osseous imaging, compared to clinically implemented photon-counting-detector (PCCT) and energy-integrating-detector (EICT) CT.Material and MethodsAn anthropomorphic hand wrist phantom underwent gantry-based CBCT (low-dose, regular, enhanced, and best settings), PCCT, and EICT. Quantitative metrics included dose values, noise, and noise power spectrum (NPS). Three radiologists with varying experience levels (10, 6, and 1 years) assessed depiction of cortical and trabecular bone, articular surfaces, intraosseous ganglion cyst, and overall image quality using 5-point Likert scales.ResultsLow-dose and regular CBCT (0.37 and 0.67 mGy) showed the lowest dose values (CTDI<sub>vol</sub>), followed by EICT, enhanced and best CBCT, and then PCCT (0.76, 1.08, and 1.61, and 3.56 mGy, respectively). Absolute noise was lowest for PCCT (15.1), followed by best (23.2), regular (25.1), and enhanced (27.4) CBCT. Highest noise was measured for low-dose CBCT (35.1) and EICT (30.1). CBCT showed overall irregular and relatively high NPS, compared to regular and high NPS of EID, whereas PCCT showed a cleaner texture with the lowest NPS. Qualitatively, CBCT (enhanced, best) generally achieved the best scores, while the other scans scored equally well. Average interreader agreement ranged from moderate to near-perfect (k = 0.53-0.87).ConclusionNovel multi-scan-body CBCT with variable image quality settings can provide detailed depiction of fine osseous structures, demonstrating comparable or lower doses compared to clinically implemented PCCT and EICT.

Authors

Institutions

Publication Details

Journal
Acta Radiologica
Published
2025-09-16
DOI
https://doi.org/10.1177/02841851251372536
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel multi-scan-body cone-beam CT: comparison with photon-counting and energy-integrating CT in an anthropomorphic hand phantom

D. Cester, Jonas Kroschke, Egon Burian, Thomas Frauenfelder et al.
Acta Radiologica
Advanced X-ray and CT Imaging
article

Novel multi-scan-body cone-beam CT: comparison with photon-counting and energy-integrating CT in an anthropomorphic hand phantom

D. Cester, Jonas Kroschke, Egon Burian, Thomas Frauenfelder, Falko Ensle, Elizabet Nikolova, Franziska Heidt
article en

Abstract

BackgroundCone-beam computed tomography (CBCT) can offer advantages over multidetector CT in dose efficiency and economic costs, but musculoskeletal applications were limited in gantry-free systems.PurposeTo assess the utility of novel multi-scan-body CBCT for osseous imaging, compared to clinically implemented photon-counting-detector (PCCT) and energy-integrating-detector (EICT) CT.Material and MethodsAn anthropomorphic hand wrist phantom underwent gantry-based CBCT (low-dose, regular, enhanced, and best settings), PCCT, and EICT. Quantitative metrics included dose values, noise, and noise power spectrum (NPS). Three radiologists with varying experience levels (10, 6, and 1 years) assessed depiction of cortical and trabecular bone, articular surfaces, intraosseous ganglion cyst, and overall image quality using 5-point Likert scales.ResultsLow-dose and regular CBCT (0.37 and 0.67 mGy) showed the lowest dose values (CTDI<sub>vol</sub>), followed by EICT, enhanced and best CBCT, and then PCCT (0.76, 1.08, and 1.61, and 3.56 mGy, respectively). Absolute noise was lowest for PCCT (15.1), followed by best (23.2), regular (25.1), and enhanced (27.4) CBCT. Highest noise was measured for low-dose CBCT (35.1) and EICT (30.1). CBCT showed overall irregular and relatively high NPS, compared to regular and high NPS of EID, whereas PCCT showed a cleaner texture with the lowest NPS. Qualitatively, CBCT (enhanced, best) generally achieved the best scores, while the other scans scored equally well. Average interreader agreement ranged from moderate to near-perfect (k = 0.53-0.87).ConclusionNovel multi-scan-body CBCT with variable image quality settings can provide detailed depiction of fine osseous structures, demonstrating comparable or lower doses compared to clinically implemented PCCT and EICT.

Acta RadiologicaVol. 67(1)
University of Zurich (CH), University Hospital of Zurich (CH)
Openalex Percentile: Top 76%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.