Accuracy Of Smart Watches In Detecting Heart Rate During Different Exercise Conditions

Smart watches (SW) have gained popularity for monitoring heart rate (HR) during daily activities and exercise. Rapid advancements in technology, including both hardware and software updates, necessitates an understanding of the accuracy of current devices and their derived metrics. Furthermore, SWs determine HR indirectly, which introduces the possibility of influence by external factors such as exercise type and intensity. PURPOSE: Evaluate the accuracy of commercially available SWs in detecting HR compared to ECG measurements across various conditions. METHODS: 169 participants (83F/86M; age: 31.9 ± 10.9 yrs; ht: 172 ± 9.95 cm; wt: 70.6 ± 12.5 kg) completed a single lab visit with three exercise trials: Treadmill (TR, 3 min stages: Rest, 4.8kph, 9kph, 12kph, 15kph); Treadmill Interval (INT, 3 repeating stages: 2 min 4.8kph and 1 min 12kph); and Cycle Ramp (CYC, 3 min stages: 50 W, 100 W, 150 W, 200 W). During each trial, participants wore 2 different consumer SWs (SW1 and SW2) on randomized wrists and were outfitted with 12-lead ECG for HR monitoring. HR from each SW was time synced with ECG and mean absolute percent error (MAPE) was calculated across trials for each SW compared to ECG data. Paired t-tests were performed on MAPE values between SW1 and SW2 for each trial. RM ANOVAs were used to assess differences within each device between the three different trials. RESULTS: SW2 reported significantly less error than SW1 in TR, INT, and CYC (p < 0.001). Both SW1 and SW2 reported significantly lower error during CYC compared to INT (SW1: p = 0.02; SW2: p < 0.001) and TR (SW1: p = 0.05; SW2: p = 0.01; Figure) Conclusions: Overall, consumer SWs demonstrate low error in HR measurements (MAPE range 1.1-3.6%) compared to ECG during a range of exercise type and intensity. SW1 provides significantly lower error in HR metrics compared to SW2. Both devices reported less error during CYC, likely resulting from differences in arm motion. Supported by: This study received funding from Samsung Electronics Co., Ltd.

Authors

Institutions

Publication Details

Journal
Medicine & Science in Sports & Exercise
Published
2025-09-16
DOI
https://doi.org/10.1249/01.mss.0001159804.64062.e9
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy Of Smart Watches In Detecting Heart Rate During Different Exercise Conditions

Adam S. Lepley, Marc Johannes, Kenneth M. Kozloff, Sarah A. Davis et al.
Medicine & Science in Sports & Exercise
Non-Invasive Vital Sign Monitoring
article

Accuracy Of Smart Watches In Detecting Heart Rate During Different Exercise Conditions

Adam S. Lepley, Marc Johannes, Kenneth M. Kozloff, Sarah A. Davis, Amanda C. Melvin, Sairub Naaz, Katherine C. Soldes, Adam P. Audet, Theodor Meingast
article en

Abstract

Smart watches (SW) have gained popularity for monitoring heart rate (HR) during daily activities and exercise. Rapid advancements in technology, including both hardware and software updates, necessitates an understanding of the accuracy of current devices and their derived metrics. Furthermore, SWs determine HR indirectly, which introduces the possibility of influence by external factors such as exercise type and intensity. PURPOSE: Evaluate the accuracy of commercially available SWs in detecting HR compared to ECG measurements across various conditions. METHODS: 169 participants (83F/86M; age: 31.9 ± 10.9 yrs; ht: 172 ± 9.95 cm; wt: 70.6 ± 12.5 kg) completed a single lab visit with three exercise trials: Treadmill (TR, 3 min stages: Rest, 4.8kph, 9kph, 12kph, 15kph); Treadmill Interval (INT, 3 repeating stages: 2 min 4.8kph and 1 min 12kph); and Cycle Ramp (CYC, 3 min stages: 50 W, 100 W, 150 W, 200 W). During each trial, participants wore 2 different consumer SWs (SW1 and SW2) on randomized wrists and were outfitted with 12-lead ECG for HR monitoring. HR from each SW was time synced with ECG and mean absolute percent error (MAPE) was calculated across trials for each SW compared to ECG data. Paired t-tests were performed on MAPE values between SW1 and SW2 for each trial. RM ANOVAs were used to assess differences within each device between the three different trials. RESULTS: SW2 reported significantly less error than SW1 in TR, INT, and CYC (p < 0.001). Both SW1 and SW2 reported significantly lower error during CYC compared to INT (SW1: p = 0.02; SW2: p < 0.001) and TR (SW1: p = 0.05; SW2: p = 0.01; Figure) Conclusions: Overall, consumer SWs demonstrate low error in HR measurements (MAPE range 1.1-3.6%) compared to ECG during a range of exercise type and intensity. SW1 provides significantly lower error in HR metrics compared to SW2. Both devices reported less error during CYC, likely resulting from differences in arm motion. Supported by: This study received funding from Samsung Electronics Co., Ltd.

Medicine & Science in Sports & ExerciseVol. 57(10S)
Washington University in St. Louis (US), University of Michigan (US)
Openalex Percentile: Top 76%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.