Fabrication of Sensitive Voltammetric Sensors and Microsensors for Piroxicam by Modifying Nafion and MWCNTs Composite Film on the Electrode Surface

Piroxicam is a common painkiller and anti-inflammatory drug.Precise monitoring of piroxicam levels can mitigate side effects, but current methods are often slow and complicated.An easily fabricated and highly sensitive voltammetric sensor for piroxicam was developed by drop-coating a composite of multi-walled carbon nanotubes (MWCNTs) and Nafion onto the electrode surface.The morphological and electrochemical characteristics of the Nafion-MWCNTs composite film were analyzed to reveal the synergistic effects of Nafion and MWCNTs.The composite film was then applied to modify a glassy carbon electrode (GCE), which served as a voltammetric sensor for the detection of piroxicam.When compared to previous reports, the sensor demonstrated efficient electrochemical oxidation of piroxicam with remarkable sensitivity, reproducibility, and stability.Under optimized conditions, the Nafion/MWCNTs/GCE exhibited a linear voltammetric response for piroxicam in the concentration range of 5 10 -9 to 8 10 -6 mol L -1 and 8 10 -6 to 6 10 -5 mol L -1 respectively, with a detection limit of 4 10 -9 mol L -1 .The sensor was successfully applied to detect piroxicam in real tablet samples, providing satisfactory recovery values.Furthermore, the composite film was applied to the surface of a platinum microelectrode, resulting in a micro-sensor for piroxicam detection.With the typical small size and the radial diffusion field, the micro-sensor of piroxicam exhibited increased sensitivity and possessed unique properties.Particularly, fast and accurate response across various piroxicam concentrations was achieved without the necessity of additional forced-convection for preconcentration, demonstrating its great potential

Authors

Institutions

Publication Details

Journal
Electrochemistry
Published
2025-09-16
DOI
https://doi.org/10.5796/electrochemistry.25-00088
Citations
1
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fabrication of Sensitive Voltammetric Sensors and Microsensors for Piroxicam by Modifying Nafion and MWCNTs Composite Film on the Electrode Surface

Weining Zhao, Jing Yang, Jie Lian, Seung Min Han et al.
1 citations
Electrochemistry
Analytical Chemistry and Sensors
0.74
article

Fabrication of Sensitive Voltammetric Sensors and Microsensors for Piroxicam by Modifying Nafion and MWCNTs Composite Film on the Electrode Surface

Weining Zhao, Jing Yang, Jie Lian, Seung Min Han, Yu Fu, Jin Li, Yue Cui, Tong Xing, Tingting Zheng, Fangyuan Zhao
article en
1 citations

Abstract

Piroxicam is a common painkiller and anti-inflammatory drug.Precise monitoring of piroxicam levels can mitigate side effects, but current methods are often slow and complicated.An easily fabricated and highly sensitive voltammetric sensor for piroxicam was developed by drop-coating a composite of multi-walled carbon nanotubes (MWCNTs) and Nafion onto the electrode surface.The morphological and electrochemical characteristics of the Nafion-MWCNTs composite film were analyzed to reveal the synergistic effects of Nafion and MWCNTs.The composite film was then applied to modify a glassy carbon electrode (GCE), which served as a voltammetric sensor for the detection of piroxicam.When compared to previous reports, the sensor demonstrated efficient electrochemical oxidation of piroxicam with remarkable sensitivity, reproducibility, and stability.Under optimized conditions, the Nafion/MWCNTs/GCE exhibited a linear voltammetric response for piroxicam in the concentration range of 5 10 -9 to 8 10 -6 mol L -1 and 8 10 -6 to 6 10 -5 mol L -1 respectively, with a detection limit of 4 10 -9 mol L -1 .The sensor was successfully applied to detect piroxicam in real tablet samples, providing satisfactory recovery values.Furthermore, the composite film was applied to the surface of a platinum microelectrode, resulting in a micro-sensor for piroxicam detection.With the typical small size and the radial diffusion field, the micro-sensor of piroxicam exhibited increased sensitivity and possessed unique properties.Particularly, fast and accurate response across various piroxicam concentrations was achieved without the necessity of additional forced-convection for preconcentration, demonstrating its great potential

ElectrochemistryVol. 93(10)
China University of Mining and Technology (CN), Shenzhen Technology University (CN), Huaiyin Institute of Technology (CN)
National Natural Science Foundation of China, Government of Jiangsu Province, Natural Science Foundation of Jiangsu Province, Wuhan University, Shenzhen Research Institute, City University of Hong Kong
Openalex Percentile: Top 27%
Analytical Chemistry and Sensors
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.