Chebyshev-polynomial-based deformable registration of magnetic resonance images with a specific application in adaptive gantry-less proton therapy

<i>Objective.</i>Efficient image guidance and online adaptive treatment are essential for the success of gantry-less proton therapy (PT). Low-field magnetic resonance imaging (MRI) is a viable option for image guidance, but scan time can limit the quality of low-field MRI images. This study aims to investigate the impact of MRI image quality on deformable image registration (DIR) performance.<i>Approach.</i>We propose a Chebyshev-polynomial-based DIR method, which calculates a mapping between the voxels of a high-quality source image and a lower-quality target image. We prepared a longitudinal breast MRI dataset and synthesized lower-quality target images with four image resolutions and noise levels. For evaluation, we assumed the registration between a pair of high-quality images as the reference registration. We calculated the root-mean-square error (RMSE) between the warped image and the reference target image, as well as between the warped images aligned with high- and lower-quality target images. Deformable vector field (DVF) errors were calculated based on the reference DVF. We obtained binary masks for glandular tissue and calculated Dice coefficients after DIR. The method was further validated with a volunteer breast MRI study with intentional movements between two scan sets and a longitudinal pelvic MRI dataset that includes two contours. Comparison studies with commercial software and open-source software were performed.<i>Main results.</i>Although the quantitative metrics worsened with higher levels of undersampling or increased noise, the RMSE between the warped and target images was substantially reduced compared to the RMSE between the source and target images before registration, even when the target images were severely degraded. Dice coefficients were also considerably increased under various image degradation scenarios.<i>Significance.</i>We have developed a Chebyshev-polynomial-based DIR method and demonstrated its performance with high-quality source and lower-quality target images. This study could help optimize MRI for adaptive gantry-less PT.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-09-16
DOI
https://doi.org/10.1088/1361-6560/ae077e
Primary Topic
Medical Image Segmentation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Chebyshev-polynomial-based deformable registration of magnetic resonance images with a specific application in adaptive gantry-less proton therapy

Thomas Bortfeld, Ali Ajdari, Samantha Hickey, G Sharp et al.
Physics in Medicine and Biology
Medical Image Segmentation Techniques
article

Chebyshev-polynomial-based deformable registration of magnetic resonance images with a specific application in adaptive gantry-less proton therapy

Thomas Bortfeld, Ali Ajdari, Samantha Hickey, G Sharp, Gregory Buti, Susu Yan, Hyeongseok Kim
article en

Abstract

<i>Objective.</i>Efficient image guidance and online adaptive treatment are essential for the success of gantry-less proton therapy (PT). Low-field magnetic resonance imaging (MRI) is a viable option for image guidance, but scan time can limit the quality of low-field MRI images. This study aims to investigate the impact of MRI image quality on deformable image registration (DIR) performance.<i>Approach.</i>We propose a Chebyshev-polynomial-based DIR method, which calculates a mapping between the voxels of a high-quality source image and a lower-quality target image. We prepared a longitudinal breast MRI dataset and synthesized lower-quality target images with four image resolutions and noise levels. For evaluation, we assumed the registration between a pair of high-quality images as the reference registration. We calculated the root-mean-square error (RMSE) between the warped image and the reference target image, as well as between the warped images aligned with high- and lower-quality target images. Deformable vector field (DVF) errors were calculated based on the reference DVF. We obtained binary masks for glandular tissue and calculated Dice coefficients after DIR. The method was further validated with a volunteer breast MRI study with intentional movements between two scan sets and a longitudinal pelvic MRI dataset that includes two contours. Comparison studies with commercial software and open-source software were performed.<i>Main results.</i>Although the quantitative metrics worsened with higher levels of undersampling or increased noise, the RMSE between the warped and target images was substantially reduced compared to the RMSE between the source and target images before registration, even when the target images were severely degraded. Dice coefficients were also considerably increased under various image degradation scenarios.<i>Significance.</i>We have developed a Chebyshev-polynomial-based DIR method and demonstrated its performance with high-quality source and lower-quality target images. This study could help optimize MRI for adaptive gantry-less PT.

Physics in Medicine and BiologyVol. 70(19)
University Medical Center Freiburg (DE), Massachusetts General Hospital (US), Harvard–MIT Division of Health Sciences and Technology (US), Massachusetts Institute of Technology (US)
Openalex Percentile: Top 76%
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.