Characteristics of partial discharge on high-density polyethylene insulation under AC and DC voltages

The majority of insulation system failures in electrical grids are caused by partial discharge (PD) activity. Continuous PD activity gradually degrades the quality of insulation, potentially resulting in total breakdown. This study investigates PD activity in high-density polyethylene (HDPE) insulation, detected through the observation and measurement of PD charge using the CIGRE Method II electrode system. The objective is to analyze PD behavior in HDPE cable insulation containing cavity-type defects under alternating current (AC) and direct current (DC). The samples consist of three layers of HDPE sheets, each 1 mm thick, with an artificial circular cavity of 1 cm in diameter embedded in the middle layer. This configuration enables detailed analysis of insulation damage and degradation. The results show that HDPE performs better under DC voltage compared to AC. This is evidenced by the average PD inception voltage (Vin) under DC conditions reaching 15.5 kV, higher than the 11.8 kV observed under AC, as well as a significantly longer PD inception time (Tin) under DC conditions. Although the PD charge magnitude is nearly the same under both voltage types, the higher voltage required to trigger PD under DC indicates that HDPE exhibits superior insulation resistance to DC voltage.

Authors

Institutions

Publication Details

Journal
International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering
Published
2025-09-09
DOI
https://doi.org/10.11591/ijece.v15i5.pp4421-4429
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characteristics of partial discharge on high-density polyethylene insulation under AC and DC voltages

Iwan Setiawan, Abdul Syakur, Yudha Agung Subarkah
International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering
High voltage insulation and dielectric phenomena
article

Characteristics of partial discharge on high-density polyethylene insulation under AC and DC voltages

Iwan Setiawan, Abdul Syakur, Yudha Agung Subarkah
article en

Abstract

The majority of insulation system failures in electrical grids are caused by partial discharge (PD) activity. Continuous PD activity gradually degrades the quality of insulation, potentially resulting in total breakdown. This study investigates PD activity in high-density polyethylene (HDPE) insulation, detected through the observation and measurement of PD charge using the CIGRE Method II electrode system. The objective is to analyze PD behavior in HDPE cable insulation containing cavity-type defects under alternating current (AC) and direct current (DC). The samples consist of three layers of HDPE sheets, each 1 mm thick, with an artificial circular cavity of 1 cm in diameter embedded in the middle layer. This configuration enables detailed analysis of insulation damage and degradation. The results show that HDPE performs better under DC voltage compared to AC. This is evidenced by the average PD inception voltage (Vin) under DC conditions reaching 15.5 kV, higher than the 11.8 kV observed under AC, as well as a significantly longer PD inception time (Tin) under DC conditions. Although the PD charge magnitude is nearly the same under both voltage types, the higher voltage required to trigger PD under DC indicates that HDPE exhibits superior insulation resistance to DC voltage.

International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer EngineeringVol. 15(5)
Diponegoro University (ID)
Openalex Percentile: Top 81%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.