Cardiac implantable electronic device infection – what’s new after the BLISTER study?

<ns3:p>Cardiac implantable electronic device (CIED) infections pose a significant challenge, with occurrence rates of 1-4% post-implantation and a 50% increased mortality risk within three years. Risk factors can expose 22-56% of patients to an elevated risk of infection, and device removal increases annual mortality by 25%. Cost analysis reveals substantial financial burdens on healthcare, averaging €7,909.58 per infection and €11,278.74 for CRT-D infections in Poland. The BLISTER risk score, based on blood results, procedure time, immunosuppression, age, intervention type, and repeat procedures, improves patient risk stratification. Compared to the PADIT score, BLISTER offers superior infection risk reduction and cost-effectiveness, making antibiotic envelopes economically justifiable. Research indicates TYRX envelopes significantly reduce infections, with BLISTER showing a greater risk reduction (30%) at a lower cost per QALY (18,446). This review examines strategies to mitigate CIED infections, focusing on both biological and non-biological envelopes for fibrous capsule formation, thereby preventing local inflammation and reducing complications during device replacement.</ns3:p>

Authors

Institutions

Publication Details

Journal
In a good rythm
Published
2025-06-30
DOI
https://doi.org/10.5604/01.3001.0055.2668
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cardiac implantable electronic device infection – what’s new after the BLISTER study?

Łukasz Grydz
In a good rythm
Cardiac pacing and defibrillation studies
article

Cardiac implantable electronic device infection – what’s new after the BLISTER study?

Łukasz Grydz
article en

Abstract

<ns3:p>Cardiac implantable electronic device (CIED) infections pose a significant challenge, with occurrence rates of 1-4% post-implantation and a 50% increased mortality risk within three years. Risk factors can expose 22-56% of patients to an elevated risk of infection, and device removal increases annual mortality by 25%. Cost analysis reveals substantial financial burdens on healthcare, averaging €7,909.58 per infection and €11,278.74 for CRT-D infections in Poland. The BLISTER risk score, based on blood results, procedure time, immunosuppression, age, intervention type, and repeat procedures, improves patient risk stratification. Compared to the PADIT score, BLISTER offers superior infection risk reduction and cost-effectiveness, making antibiotic envelopes economically justifiable. Research indicates TYRX envelopes significantly reduce infections, with BLISTER showing a greater risk reduction (30%) at a lower cost per QALY (18,446). This review examines strategies to mitigate CIED infections, focusing on both biological and non-biological envelopes for fibrous capsule formation, thereby preventing local inflammation and reducing complications during device replacement.</ns3:p>

In a good rythmVol. 4(73)
Jan Kochanowski University (PL)
Openalex Percentile: Top 62%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.