A Novel Rolling Driving Principle-Enabled Linear Actuator for Bidirectional Smooth Motion

This work presents a novel rolling driving principle (RDP) for stick-slip actuators to achieve high motion consistency, inspired by the rack-and-pinion mechanism. This RDP utilizes a symmetrical driving structure and tangential contact to realize the pure rolling motion between the stator and the slider, requiring just a single lead zirconate titanate (PZT). This configuration ensures a consistent bidirectional driving process with a constant contact force, which improves both motion consistency and linearity. Based on this RDP principle, a linear stick-slip actuator incorporating an isosceles trapezoidal flexible mechanism (ITFM) has been implemented. The corresponding driving principle, operating principle, and the RDP's advantages have been analyzed and revealed. Design optimization was performed to investigate the optimal structural parameters of the ITFM. The superior performance of the proposed RDP-type actuator was experimentally verified across both high- and low-frequency ranges. The results indicate that the presented design exhibits forward and reverse output speed values of 0.410 and 0.417 mm/s at 10 Hz with linear correlation coefficients of 0.99969 and 0.99962, indicating an excellent motion consistency with a velocity difference ratio of 1.96%. When working at 560 Hz, the presented actuator reaches 37.73 and 34.99 mm/s for the forward and reverse output speed, yielding high linearity values of 0.99999 and 0.99999 due to the tiny speed fluctuation, and maintains a reasonable motion consistency with a velocity difference ratio of 7.54%. Finally, an RDP-type actuator-based magnetic resonance imaging (MRI)-compatible microsurgical instrument was proposed and prototyped, which enables opening-closing motions and cutting motions for intraoperative MRI surgical applications.

Authors

Institutions

Publication Details

Journal
Cyborg and Bionic Systems
Published
2025-09-09
DOI
https://doi.org/10.34133/cbsystems.0424
Primary Topic
Vehicle Dynamics and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Rolling Driving Principle-Enabled Linear Actuator for Bidirectional Smooth Motion

Chaoyang Shi, Dunfa Long, Chengzhi Hu, Fujun Wang
Cyborg and Bionic Systems
Vehicle Dynamics and Control Systems
article

A Novel Rolling Driving Principle-Enabled Linear Actuator for Bidirectional Smooth Motion

Chaoyang Shi, Dunfa Long, Chengzhi Hu, Fujun Wang
article en

Abstract

This work presents a novel rolling driving principle (RDP) for stick-slip actuators to achieve high motion consistency, inspired by the rack-and-pinion mechanism. This RDP utilizes a symmetrical driving structure and tangential contact to realize the pure rolling motion between the stator and the slider, requiring just a single lead zirconate titanate (PZT). This configuration ensures a consistent bidirectional driving process with a constant contact force, which improves both motion consistency and linearity. Based on this RDP principle, a linear stick-slip actuator incorporating an isosceles trapezoidal flexible mechanism (ITFM) has been implemented. The corresponding driving principle, operating principle, and the RDP's advantages have been analyzed and revealed. Design optimization was performed to investigate the optimal structural parameters of the ITFM. The superior performance of the proposed RDP-type actuator was experimentally verified across both high- and low-frequency ranges. The results indicate that the presented design exhibits forward and reverse output speed values of 0.410 and 0.417 mm/s at 10 Hz with linear correlation coefficients of 0.99969 and 0.99962, indicating an excellent motion consistency with a velocity difference ratio of 1.96%. When working at 560 Hz, the presented actuator reaches 37.73 and 34.99 mm/s for the forward and reverse output speed, yielding high linearity values of 0.99999 and 0.99999 due to the tiny speed fluctuation, and maintains a reasonable motion consistency with a velocity difference ratio of 7.54%. Finally, an RDP-type actuator-based magnetic resonance imaging (MRI)-compatible microsurgical instrument was proposed and prototyped, which enables opening-closing motions and cutting motions for intraoperative MRI surgical applications.

Cyborg and Bionic SystemsVol. 7
Tianjin University (CN), Southern University of Science and Technology (CN), Ministry of Education (KN)
Openalex Percentile: Top 73%
Vehicle Dynamics and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.