Influence of Misalignment on Track Reconstruction in the Time Projection Chamber of the MultiPurpose Detector (MTD)

Using the previously developed alignment method for the Time Projection Chamber (TPC) in the MPD detector, the in uence of misalignment on the reconstructed parameters of a charged particle track, such as transverse momentum and rapidity, is studied. The concept of a misalignment unit is introduced for the TPC. By simulating the TPC response to charged particles, distortions in the reconstructed track parameters depending on the magnitude of misalignment are analyzed. The ifluence of alignment errors on the reconstructed track parameters in the MPD TPC can be neglected. A systematic variation of the measured transverse momentum depending on the track projection width onto the readout plane is observed. This width is determined by the gas conditions and the electric field in the detector chamber. The alignment tools developed for the MPD Time Projection Chamber make it possible to estimate this width from experimental data and apply corrections to the reconstructed track parameters.

Authors

Institutions

Publication Details

Journal
Vestnik Moskovskogo Universiteta Seriya 3 Fizika Astronomiya
Published
2025-01-01
DOI
https://doi.org/10.55959/msu0579-9392.80.2530204
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Misalignment on Track Reconstruction in the Time Projection Chamber of the MultiPurpose Detector (MTD)

V. A. Kuzmin
Vestnik Moskovskogo Universiteta Seriya 3 Fizika Astronomiya
Particle Detector Development and Performance
article

Influence of Misalignment on Track Reconstruction in the Time Projection Chamber of the MultiPurpose Detector (MTD)

V. A. Kuzmin
article en

Abstract

Using the previously developed alignment method for the Time Projection Chamber (TPC) in the MPD detector, the in uence of misalignment on the reconstructed parameters of a charged particle track, such as transverse momentum and rapidity, is studied. The concept of a misalignment unit is introduced for the TPC. By simulating the TPC response to charged particles, distortions in the reconstructed track parameters depending on the magnitude of misalignment are analyzed. The ifluence of alignment errors on the reconstructed track parameters in the MPD TPC can be neglected. A systematic variation of the measured transverse momentum depending on the track projection width onto the readout plane is observed. This width is determined by the gas conditions and the electric field in the detector chamber. The alignment tools developed for the MPD Time Projection Chamber make it possible to estimate this width from experimental data and apply corrections to the reconstructed track parameters.

Vestnik Moskovskogo Universiteta Seriya 3 Fizika AstronomiyaVol. 80(№3, 2025)
Lomonosov Moscow State University (RU), Moscow State University (TJ)
Openalex Percentile: Top 90%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Influence of Misalignment on Track Reconstruction in the Time Projection Chamber of the MultiPurpose Detector (MTD) — V. A. Kuzmin · Vestnik Moskovskogo Universiteta Seriya 3 Fizika Astronomiya (2025) | TGRS Research Map | TGRS