Single time-point kidney dosimetry in 177Lu-PSMA therapy: A comparison between AI-based and manual segmentation approaches

Background: Single time-point (STP) dosimetry has become a practical and efficient approach for personalised radioligand therapy (RLT), with 48-hours post-injection identified as optimal for kidney dose estimation in ¹⁷⁷Lu-PSMA therapy for prostate cancer. However, segmentation accuracy remains a critical factor affecting dosimetry reliability. AI-based segmentation has recently been integrated into commercial software to improve efficiency and reduce variability. Objectives: This study aims to quantify kidney absorbed doses in patients receiving ¹⁷⁷Lu-PSMA therapy using STP dosimetry and to compare the accuracy and consistency of AI-based segmentation versus manual segmentation techniques. Materials and methods: Eight treatment cycles from 5 patients of ¹⁷⁷Lu-PSMA were retrospectively analysed. In this work, whole-body SPECT/CT imaging was performed approximately 48 hours post-injection. Then, kidney dosimetry was calculated using voxel-based STP (Hänscheid method) within MIM SurePlan™ MRT software. Kidney volumes of interest (VOIs) were segmented using three approaches: 1) AI-based automatic segmentation, 2) AI-based with manual refinement, and 3) fully manual segmentation. Mean absorbed doses and VOI volumes were compared across methods. Statistical analyses included ANOVA, Dice Similarity Coefficient (DSC), and Jaccard Similarity Coefficient (JSC). Results: No significant differences in mean kidney absorbed doses were found across segmentation methods (p=0.964), while kidney VOI volumes showed significant variation (p<0.05). AI-based segmentation achieved high concordance with manual delineation (DSC: 0.898±0.019; JSC: 0.816±0.031). Conclusion: AI-based segmentation provides comparable absorbed dose results to manual segmentation, with reduced time and inter-observer variability.

Authors

Publication Details

Journal
Journal of Associated Medical Sciences
Published
2025-09-09
DOI
https://doi.org/10.12982/jams.2026.002
Primary Topic
Prostate Cancer Treatment and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single time-point kidney dosimetry in 177Lu-PSMA therapy: A comparison between AI-based and manual segmentation approaches

Putthiporn Charoenphun, Krisanat Chuamsaamarkkee, Wichana Chamroonrat, Thitaya Chaiwongsa
Journal of Associated Medical Sciences
Prostate Cancer Treatment and Research
article

Single time-point kidney dosimetry in 177Lu-PSMA therapy: A comparison between AI-based and manual segmentation approaches

Putthiporn Charoenphun, Krisanat Chuamsaamarkkee, Wichana Chamroonrat, Thitaya Chaiwongsa
article en

Abstract

Background: Single time-point (STP) dosimetry has become a practical and efficient approach for personalised radioligand therapy (RLT), with 48-hours post-injection identified as optimal for kidney dose estimation in ¹⁷⁷Lu-PSMA therapy for prostate cancer. However, segmentation accuracy remains a critical factor affecting dosimetry reliability. AI-based segmentation has recently been integrated into commercial software to improve efficiency and reduce variability. Objectives: This study aims to quantify kidney absorbed doses in patients receiving ¹⁷⁷Lu-PSMA therapy using STP dosimetry and to compare the accuracy and consistency of AI-based segmentation versus manual segmentation techniques. Materials and methods: Eight treatment cycles from 5 patients of ¹⁷⁷Lu-PSMA were retrospectively analysed. In this work, whole-body SPECT/CT imaging was performed approximately 48 hours post-injection. Then, kidney dosimetry was calculated using voxel-based STP (Hänscheid method) within MIM SurePlan™ MRT software. Kidney volumes of interest (VOIs) were segmented using three approaches: 1) AI-based automatic segmentation, 2) AI-based with manual refinement, and 3) fully manual segmentation. Mean absorbed doses and VOI volumes were compared across methods. Statistical analyses included ANOVA, Dice Similarity Coefficient (DSC), and Jaccard Similarity Coefficient (JSC). Results: No significant differences in mean kidney absorbed doses were found across segmentation methods (p=0.964), while kidney VOI volumes showed significant variation (p<0.05). AI-based segmentation achieved high concordance with manual delineation (DSC: 0.898±0.019; JSC: 0.816±0.031). Conclusion: AI-based segmentation provides comparable absorbed dose results to manual segmentation, with reduced time and inter-observer variability.

Journal of Associated Medical SciencesVol. 59(1)
Openalex Percentile: Top 64%
Prostate Cancer Treatment and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Single time-point kidney dosimetry in 177Lu-PSMA therapy: A comparison between AI-based and manual segmentation approaches — Putthiporn Charoenphun, Krisanat Chuamsaamarkkee, et al. · Journal of Associated Medical Sciences (2025) | TGRS Research Map | TGRS