Validating CFD Models for VAWT Wind Turbines: Considering Wind Flow Blockage Over a Roof Ridge

<ns3:p>This article examines how increased wind flow velocity above the ridge of a gable roof influences the torque generated by a Savonius wind turbine. The study consisted of two stages: numerical simulations using SolidWorks Flow Simulation, and quasi-static wind tunnel measurements. The primary aim was to validate a simplified numerical model using experimental data, considering varying geometric parameters: specifically, roof pitch angles (30, 45, 60) and the distance from the turbine's axis to the roof ridge (450–710 mm). A grid sensitivity analysis was performed, and torque values were compared as a function of the rotor's angle of rotation. The observed flow blockage over the ridge resulted in a significant increase in torque, underscoring the importance of strategically positioning the wind turbine where wind speeds are highest. These findings can inform the optimal placement of small VAWT systems in urban settings.</ns3:p>

Authors

Institutions

Publication Details

Journal
Problems of Mechatronics Armament Aviation Safety Engineering
Published
2025-09-09
DOI
https://doi.org/10.5604/01.3001.0055.2663
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validating CFD Models for VAWT Wind Turbines: Considering Wind Flow Blockage Over a Roof Ridge

Bartosz Moczulak, Wojciech Miąskowski, Magdalena Zielińska, Alexis Martin et al.
Problems of Mechatronics Armament Aviation Safety Engineering
Wind and Air Flow Studies
article

Validating CFD Models for VAWT Wind Turbines: Considering Wind Flow Blockage Over a Roof Ridge

Bartosz Moczulak, Wojciech Miąskowski, Magdalena Zielińska, Alexis Martin, Szymon BAJKOWSKI
article en

Abstract

<ns3:p>This article examines how increased wind flow velocity above the ridge of a gable roof influences the torque generated by a Savonius wind turbine. The study consisted of two stages: numerical simulations using SolidWorks Flow Simulation, and quasi-static wind tunnel measurements. The primary aim was to validate a simplified numerical model using experimental data, considering varying geometric parameters: specifically, roof pitch angles (30, 45, 60) and the distance from the turbine's axis to the roof ridge (450–710 mm). A grid sensitivity analysis was performed, and torque values were compared as a function of the rotor's angle of rotation. The observed flow blockage over the ridge resulted in a significant increase in torque, underscoring the importance of strategically positioning the wind turbine where wind speeds are highest. These findings can inform the optimal placement of small VAWT systems in urban settings.</ns3:p>

Problems of Mechatronics Armament Aviation Safety EngineeringVol. 16(3)
Institut Catholique d'Arts et Métiers (FR), University of Warmia and Mazury in Olsztyn (PL)
Openalex Percentile: Top 77%
Wind and Air Flow Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Validating CFD Models for VAWT Wind Turbines: Considering Wind Flow Blockage Over a Roof Ridge — Bartosz Moczulak, Wojciech Miąskowski, et al. · Problems of Mechatronics Armament Aviation Safety Engineering (2025) | TGRS Research Map | TGRS