Intraoperative Arterial Blood Flow and Stump Pressure Measurements in Internal Carotid Artery Near‐Occlusion

Near‐occlusion (NO) with and without full collapse seems to cause low blood flow in symptomatic carotid stenosis. If the stroke mechanism is hypoperfusion in NO, the stump pressure should be low. The aim was to compare and describe stump pressure and blood flow in conventional ≥ 50% stenosis, NO without full collapse, and NO with full collapse. In this prospective single‐center study, consecutive patients with symptomatic ≥ 50% carotid stenosis (NASCET grading), undergoing carotid endarterectomy (CEA) were recruited. NO was diagnosed by three blinded observers who reviewed computed tomography angiographies (CTA). Intraoperative measurements of ICA flow before and after CEA and stump pressure were recorded. One hundred and eighty‐one patients were included; 116 (64%) had conventional ≥ 50% stenosis, and 66 (36%) had NO. Before CEA, the median ICA flow was significantly lower in NO (90 ml/min) compared to conventional ≥ 50% stenosis (170 mL/min, p < 0.001). In contrast, no difference was observed after CEA (NO 170 mL/min, conventional ≥ 50% stenosis 180 mL/min, p = 0.48). The ICA flow change was significantly higher in NO compared to conventional stenosis ( p < 0.001). There was a significant correlation between the distal ICA diameter on CTA and the ICA flow before CEA ( r = 0.579, p < 0.001). There were no differences in stump pressure between NO and conventional ≥ 50% stenoses (median 53 (range 41–66) mmHg and median 54 (range 40–67) mmHg, respectively, p = 0.93), nor any correlation between the stump pressure and the distal ICA diameter ( r = 0.063, p = 0.41). NO causes low ICA flow, and to our knowledge, this is the first time this causal link between ICA flow and NO is clearly established. Since patients with NO did not have low stump pressure, the mechanism of stroke in NO does not seem to be hypoperfusion.

Authors

Institutions

Publication Details

Journal
Acta Neurologica Scandinavica
Published
2025-01-01
DOI
https://doi.org/10.1155/ane/4620206
Primary Topic
Cerebrovascular and Carotid Artery Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intraoperative Arterial Blood Flow and Stump Pressure Measurements in Internal Carotid Artery Near‐Occlusion

Mari Holsti, Alexander Henze, Annika Nordanstig, Joakim Nordanstig et al.
Acta Neurologica Scandinavica
Cerebrovascular and Carotid Artery Diseases
article

Intraoperative Arterial Blood Flow and Stump Pressure Measurements in Internal Carotid Artery Near‐Occlusion

Mari Holsti, Alexander Henze, Annika Nordanstig, Joakim Nordanstig, Mahia Aivaz Ihari, Allan J. Fox, Sofia Strömberg, Elias Johansson
article en

Abstract

Near‐occlusion (NO) with and without full collapse seems to cause low blood flow in symptomatic carotid stenosis. If the stroke mechanism is hypoperfusion in NO, the stump pressure should be low. The aim was to compare and describe stump pressure and blood flow in conventional ≥ 50% stenosis, NO without full collapse, and NO with full collapse. In this prospective single‐center study, consecutive patients with symptomatic ≥ 50% carotid stenosis (NASCET grading), undergoing carotid endarterectomy (CEA) were recruited. NO was diagnosed by three blinded observers who reviewed computed tomography angiographies (CTA). Intraoperative measurements of ICA flow before and after CEA and stump pressure were recorded. One hundred and eighty‐one patients were included; 116 (64%) had conventional ≥ 50% stenosis, and 66 (36%) had NO. Before CEA, the median ICA flow was significantly lower in NO (90 ml/min) compared to conventional ≥ 50% stenosis (170 mL/min, p < 0.001). In contrast, no difference was observed after CEA (NO 170 mL/min, conventional ≥ 50% stenosis 180 mL/min, p = 0.48). The ICA flow change was significantly higher in NO compared to conventional stenosis ( p < 0.001). There was a significant correlation between the distal ICA diameter on CTA and the ICA flow before CEA ( r = 0.579, p < 0.001). There were no differences in stump pressure between NO and conventional ≥ 50% stenoses (median 53 (range 41–66) mmHg and median 54 (range 40–67) mmHg, respectively, p = 0.93), nor any correlation between the stump pressure and the distal ICA diameter ( r = 0.063, p = 0.41). NO causes low ICA flow, and to our knowledge, this is the first time this causal link between ICA flow and NO is clearly established. Since patients with NO did not have low stump pressure, the mechanism of stroke in NO does not seem to be hypoperfusion.

Acta Neurologica ScandinavicaVol. 2025(1)
Sunnybrook Health Science Centre (CA), University of Gothenburg (SE), Umeå University (SE)
Openalex Percentile: Top 64%
Cerebrovascular and Carotid Artery Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.