THE IMPORTANCE OF DISSOLVED GAS ANALYSIS DURING FACTORY ACCEPTANCE TESTS

Dissolved gas analyses (DGA) of oil are routinely used as a standard quality control procedure during factory tests of power transformers. The factory acceptance tests (FAT) represent the final and critical step in ensuring quality before the transformer leaves the factory. This paper discusses the significance of dissolved gas analysis within the context of factory testing of transformers. Several cases demonstrating different oil analysis protocols applied to both, new and repaired transformers were presented. Recommendations are provided for enhancing the factory tests for overhauled transformers to verify the repairs conducted before they leave the factory and are put into operation.

Authors

Publication Details

Published
2025-01-01
DOI
https://doi.org/10.46793/cigre37.a2.08
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

THE IMPORTANCE OF DISSOLVED GAS ANALYSIS DURING FACTORY ACCEPTANCE TESTS

Đorđe Jovanović, Vesna Radin, Miloš Brdarević, Branka Đurić
Power Transformer Diagnostics and Insulation
article

THE IMPORTANCE OF DISSOLVED GAS ANALYSIS DURING FACTORY ACCEPTANCE TESTS

Đorđe Jovanović, Vesna Radin, Miloš Brdarević, Branka Đurić
article en

Abstract

Dissolved gas analyses (DGA) of oil are routinely used as a standard quality control procedure during factory tests of power transformers. The factory acceptance tests (FAT) represent the final and critical step in ensuring quality before the transformer leaves the factory. This paper discusses the significance of dissolved gas analysis within the context of factory testing of transformers. Several cases demonstrating different oil analysis protocols applied to both, new and repaired transformers were presented. Recommendations are provided for enhancing the factory tests for overhauled transformers to verify the repairs conducted before they leave the factory and are put into operation.

Openalex Percentile: Top 76%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.