Test Specific Quality Control Plan: Maximum Run Size

ABSTRACT Purpose : Internal quality control (QC) is an essential component of ensuring reliability in laboratory operations, with risk planning becoming increasingly critical in recent times. While each test varies in terms of demand and workload, the frequency of internal QC must be carefully determined. Adopting a test specific QC plan, rather than a generalized approach, allows for early detection of potential issues unique to each test, enabling timely corrective actions. According to the CLSI EP23 guideline, every laboratory should establish a tailored QC plan for each test to enhance accuracy, mitigate risks, and improve overall quality management. Methods : In our study, we aim to determine the maximum analytical CV values achievable by calculating Max E(Nuf) (the expected number of unreliable final results before the last accepted quality control) and maximum run size data. These calculations will be based on Rilibäk TEa (Total Allowable Error) targets and laboratory workflow frequency for Glucose and Sodium (Na) tests, using the QC Constellation program in accordance with the CLSI EP23 guideline. Results : Analytical CV values determined before the max E(Nuf) value exceeded 1 were 2.13 and 0.58 for glucose and Na, respectively. When the CV value for glucose increased to 2.83 and 0.78 for Na, the RMI value exceeded 1, indicating that the QC scheme was no longer at a controllable level. Conclusion : Each laboratory should develop a test specific quality control (QC) plan tailored to its unique workload and operational volume.

Authors

Institutions

Publication Details

Journal
Acibadem Universitesi Saglik Bilimleri Dergisi
Published
2025-09-09
DOI
https://doi.org/10.31067/acusaglik.1623573
Primary Topic
Quality and Safety in Healthcare
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Test Specific Quality Control Plan: Maximum Run Size

Çoskun Çavuşoğlu
Acibadem Universitesi Saglik Bilimleri Dergisi
Quality and Safety in Healthcare
article

Test Specific Quality Control Plan: Maximum Run Size

Çoskun Çavuşoğlu
article en

Abstract

ABSTRACT Purpose : Internal quality control (QC) is an essential component of ensuring reliability in laboratory operations, with risk planning becoming increasingly critical in recent times. While each test varies in terms of demand and workload, the frequency of internal QC must be carefully determined. Adopting a test specific QC plan, rather than a generalized approach, allows for early detection of potential issues unique to each test, enabling timely corrective actions. According to the CLSI EP23 guideline, every laboratory should establish a tailored QC plan for each test to enhance accuracy, mitigate risks, and improve overall quality management. Methods : In our study, we aim to determine the maximum analytical CV values achievable by calculating Max E(Nuf) (the expected number of unreliable final results before the last accepted quality control) and maximum run size data. These calculations will be based on Rilibäk TEa (Total Allowable Error) targets and laboratory workflow frequency for Glucose and Sodium (Na) tests, using the QC Constellation program in accordance with the CLSI EP23 guideline. Results : Analytical CV values determined before the max E(Nuf) value exceeded 1 were 2.13 and 0.58 for glucose and Na, respectively. When the CV value for glucose increased to 2.83 and 0.78 for Na, the RMI value exceeded 1, indicating that the QC scheme was no longer at a controllable level. Conclusion : Each laboratory should develop a test specific quality control (QC) plan tailored to its unique workload and operational volume.

Acibadem Universitesi Saglik Bilimleri DergisiVol. 16(4)
Ümraniye Eğitim ve Araştırma Hastanesi (TR)
Openalex Percentile: Top 55%
Quality and Safety in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.