Single Axis Pneumatic Modular Hip Joint for Hip Disarticulation Amputees

The single-axis pneumatic modular hip joint is a pivotal component in hip disarticulation prostheses, addressing the needs of a niche but highly challenged amputee population (2% of amputees) facing high energy expenditure (200% of normal ambulation) and prosthesis rejection rates. This study aimed to develop a lightweight, low-cost, pneumatic single-axis hip joint tailored for K2 and K3 activity levels in developing countries like India, prioritizing affordability, stance-phase stability, swing-phase control, and ease of use. The methodology involved design conceptualization, precise measurements (joint length: 225 mm, width: 90 mm), cost-effective material selection (locally sourced steel pneumatic cylinder, aluminum, and stainless steel), and meticulous fabrication for seamless integration with modular prosthetic components, including a molded socket, polycentric knee, and SACH foot. Motion analysis and clinical evaluations demonstrated a 30% reduction in stance-phase sway, 20–30% improvement in gait cadence variability, and 25% enhanced stride symmetry, enabling independent ambulation without axillary aids. The design, costing 80–90% less than commercial alternatives (e.g., Ottobock 7E5), leverages a $20–$30 pneumatic cylinder and withstands over 500,000 gait cycles. Despite its slightly massive construction (600 grams), potentially affecting long-term comfort, the joint offers a scalable, reliable solution for low-income settings. Future improvements could include lighter materials and customizable resistance to enhance performance, making this indigenous design a transformative step in improving mobility and quality of life for hip disarticulation amputees in resource-constrained environments.

Authors

Publication Details

Journal
International Journal of Research and Innovation in Applied Science
Published
2025-01-01
DOI
https://doi.org/10.51584/ijrias.2025.100800075
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single Axis Pneumatic Modular Hip Joint for Hip Disarticulation Amputees

Sushree Sangita Nayak, Srikanta Maharana, Kshyanaprava Senapati
International Journal of Research and Innovation in Applied Science
Orthopaedic implants and arthroplasty
article

Single Axis Pneumatic Modular Hip Joint for Hip Disarticulation Amputees

Sushree Sangita Nayak, Srikanta Maharana, Kshyanaprava Senapati
article en

Abstract

The single-axis pneumatic modular hip joint is a pivotal component in hip disarticulation prostheses, addressing the needs of a niche but highly challenged amputee population (2% of amputees) facing high energy expenditure (200% of normal ambulation) and prosthesis rejection rates. This study aimed to develop a lightweight, low-cost, pneumatic single-axis hip joint tailored for K2 and K3 activity levels in developing countries like India, prioritizing affordability, stance-phase stability, swing-phase control, and ease of use. The methodology involved design conceptualization, precise measurements (joint length: 225 mm, width: 90 mm), cost-effective material selection (locally sourced steel pneumatic cylinder, aluminum, and stainless steel), and meticulous fabrication for seamless integration with modular prosthetic components, including a molded socket, polycentric knee, and SACH foot. Motion analysis and clinical evaluations demonstrated a 30% reduction in stance-phase sway, 20–30% improvement in gait cadence variability, and 25% enhanced stride symmetry, enabling independent ambulation without axillary aids. The design, costing 80–90% less than commercial alternatives (e.g., Ottobock 7E5), leverages a $20–$30 pneumatic cylinder and withstands over 500,000 gait cycles. Despite its slightly massive construction (600 grams), potentially affecting long-term comfort, the joint offers a scalable, reliable solution for low-income settings. Future improvements could include lighter materials and customizable resistance to enhance performance, making this indigenous design a transformative step in improving mobility and quality of life for hip disarticulation amputees in resource-constrained environments.

International Journal of Research and Innovation in Applied ScienceVol. X(VIII)
Openalex Percentile: Top 60%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.