4D flow MRI enhances prototype testing of a total artificial heart

The shortage of donor hearts urges the need for total artificial hearts (TAHs). Existing TAHs cause complications like infection, stroke, and hemolysis due to adverse flow dynamics, but assessment of flow in a TAH is challenging. We investigated the feasibility of using 4D flow magnetic resonance imaging (MRI) to assess blood flow dynamics in the left side of a pulsatile TAH under representative physiological conditions. A prototype of a pulsatile TAH was modified using powder bed fusion and fused filament fabrication 3D printing techniques to function in an MRI environment. The TAH connected to an MRI compatible mock circulatory loop allowed variable physiological conditions (i.e. heart rate 80, 105, 120 bpm) and was scanned with two different velocity encodings. Flow patterns and turbulent kinetic energy were measured with high accuracy in a short measurement time and analyzed. Stasis and viscous energy loss in the artificial heart were found to be similar to healthy native hearts. Elevated turbulent kinetic energy was found in several areas, but values were well below those found in patients with valvular disease. Using 4D flow MRI in combination with 3D printing can facilitate assessment of flow dynamics in TAHs and enable a rapid iterative design process.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-09-15
DOI
https://doi.org/10.1038/s41598-025-18422-y
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

4D flow MRI enhances prototype testing of a total artificial heart

Thomas Finocchiaro, T. Bakker, Azad Najar, Jonas Lantz et al.
Scientific Reports
Cardiac Valve Diseases and Treatments
article

4D flow MRI enhances prototype testing of a total artificial heart

Thomas Finocchiaro, T. Bakker, Azad Najar, Jonas Lantz, Tino Ebbers, Ina Laura Perkins
article en

Abstract

The shortage of donor hearts urges the need for total artificial hearts (TAHs). Existing TAHs cause complications like infection, stroke, and hemolysis due to adverse flow dynamics, but assessment of flow in a TAH is challenging. We investigated the feasibility of using 4D flow magnetic resonance imaging (MRI) to assess blood flow dynamics in the left side of a pulsatile TAH under representative physiological conditions. A prototype of a pulsatile TAH was modified using powder bed fusion and fused filament fabrication 3D printing techniques to function in an MRI environment. The TAH connected to an MRI compatible mock circulatory loop allowed variable physiological conditions (i.e. heart rate 80, 105, 120 bpm) and was scanned with two different velocity encodings. Flow patterns and turbulent kinetic energy were measured with high accuracy in a short measurement time and analyzed. Stasis and viscous energy loss in the artificial heart were found to be similar to healthy native hearts. Elevated turbulent kinetic energy was found in several areas, but values were well below those found in patients with valvular disease. Using 4D flow MRI in combination with 3D printing can facilitate assessment of flow dynamics in TAHs and enable a rapid iterative design process.

Scientific ReportsVol. 15(1)
Linköping University (SE)
Linköpings Universitet
Openalex Percentile: Top 62%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.