Experimental Study of the Effectiveness of Strengthening Reinforced Concrete Slabs with Thermally Prestressed Reinforcement

Conventional strengthening measures for existing structures are usually not effective for the self-weight, which accounts for around 70% of the total load in reinforced concrete structures. Therefore, their effect on the overall load-bearing capacity is low. A self-weight-effective alternative for flexural strengthening is the thermal prestressing of additional reinforcement installed on the structure. In this method, reinforcing bars are slotted into the tensile zone, embedded in filler material, and tempered from the outside. They are thermally stretched, and once cooling starts, the bond with the hardened filler prevents re-deformation. The induced prestressing force counteracts dead loads and relieves the tensile zone, making the additional bars effective for the self-weight. In this paper, the effectiveness of the strengthening method is experimentally investigated in the serviceability and the ultimate limit states. Experiments involve strengthening a reinforced concrete beam under load by a thermally prestressed additional bar. Moreover, two reference tests are made to evaluate the method. An unstrengthened beam characterizes the lower capacity limit. Another beam with the same reinforcement amount as the strengthened one, but completely installed at casting, serves as the upper benchmark. All beams are loaded until bending failure. The strengthening method is assessed by means of the load-bearing behavior, deflection, crack development, and the strains in the initial as well as the added reinforcement. The results demonstrate the effectiveness of the strengthening method. The thermally prestressed bar achieves an effective pre-strain of approximately. 0.4‰ by heating at about 70 °C. The induced prestressing force and associated compression reduce tensile cracks by approx. 45% and increase stiffness. The strengthened beam reaches the maximum load of the upper benchmark, but with about 33% less deflection. The filler, which also expands thermally, generates an additional prestressing force that is effective up to about 20% of the load capacity. Beyond this, the filler begins to crack and its effect decreases, but the pre-strain in the reinforcing bar remains until maximum load.

Authors

Institutions

Publication Details

Journal
CivilEng
Published
2025-09-13
DOI
https://doi.org/10.3390/civileng6030049
Citations
2
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
1.91

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Study of the Effectiveness of Strengthening Reinforced Concrete Slabs with Thermally Prestressed Reinforcement

David Sanio, Peter Mark, Yannik Schwarz
2 citations
CivilEng
Fire effects on concrete materials
1.91
article

Experimental Study of the Effectiveness of Strengthening Reinforced Concrete Slabs with Thermally Prestressed Reinforcement

David Sanio, Peter Mark, Yannik Schwarz
article en
2 citations

Abstract

Conventional strengthening measures for existing structures are usually not effective for the self-weight, which accounts for around 70% of the total load in reinforced concrete structures. Therefore, their effect on the overall load-bearing capacity is low. A self-weight-effective alternative for flexural strengthening is the thermal prestressing of additional reinforcement installed on the structure. In this method, reinforcing bars are slotted into the tensile zone, embedded in filler material, and tempered from the outside. They are thermally stretched, and once cooling starts, the bond with the hardened filler prevents re-deformation. The induced prestressing force counteracts dead loads and relieves the tensile zone, making the additional bars effective for the self-weight. In this paper, the effectiveness of the strengthening method is experimentally investigated in the serviceability and the ultimate limit states. Experiments involve strengthening a reinforced concrete beam under load by a thermally prestressed additional bar. Moreover, two reference tests are made to evaluate the method. An unstrengthened beam characterizes the lower capacity limit. Another beam with the same reinforcement amount as the strengthened one, but completely installed at casting, serves as the upper benchmark. All beams are loaded until bending failure. The strengthening method is assessed by means of the load-bearing behavior, deflection, crack development, and the strains in the initial as well as the added reinforcement. The results demonstrate the effectiveness of the strengthening method. The thermally prestressed bar achieves an effective pre-strain of approximately. 0.4‰ by heating at about 70 °C. The induced prestressing force and associated compression reduce tensile cracks by approx. 45% and increase stiffness. The strengthened beam reaches the maximum load of the upper benchmark, but with about 33% less deflection. The filler, which also expands thermally, generates an additional prestressing force that is effective up to about 20% of the load capacity. Beyond this, the filler begins to crack and its effect decreases, but the pre-strain in the reinforcing bar remains until maximum load.

CivilEngVol. 6(3)
Ruhr University Bochum (DE)
Deutsche Forschungsgemeinschaft
Openalex Percentile: Top 13%
Fire effects on concrete materials
1.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.