Evaluation of Commercial Camera-Based Solutions for Tracking Hand Kinematics

Tracking hand kinematics is essential for numerous clinical and scientific applications. Markerless motion capture devices have advantages over other modalities in terms of calibration, set up, and overall ease of use; however, their accuracy during dynamic tasks has not been fully explored. This study examined the performance of two popular markerless systems, the Leap Motion Controller 2 (LM2) and MediaPipe (MP), in capturing joint motion of the digits. Data were compared to joint motion collected from a marker-based multi-camera system (Vicon). Eleven participants performed six tasks with their dominant right hand at three movement speeds while all three devices simultaneously captured the position of hand landmarks. Using these data, digit joint angles were calculated. The root mean squared error (RMSE) and correlation coefficient (<i>r</i>) relative to the Vicon angles were computed for LM2 and MP. LM2 achieved a lower error (<i>p</i> < 0.001, mean RMSE = 14.8°) and a higher correlation (<i>p</i> = 0.007, mean <i>r</i> = 0.58) than the MP system (mean RMSE = 22.5°, mean <i>r</i> = 0.45). Greater movement speed led to significantly higher RMSE (<i>p</i> < 0.001) and lower <i>r</i> (<i>p</i> < 0.001) for MP but not for LM2. Error was substantially greater for the proximal interphalangeal joint than for other finger joints, although <i>r</i> values were higher for this joint. Overall, the LM2 and MP systems were able to capture motion at the joint level across digits for a variety of tasks in real time, although the level of error may not be acceptable for certain applications.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-09-13
DOI
https://doi.org/10.3390/s25185716
Citations
1
Primary Topic
Hand Gesture Recognition Systems
Type
article
Field-Weighted Citation Impact
1.94

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Commercial Camera-Based Solutions for Tracking Hand Kinematics

Christopher Vogel, Derek G. Kamper, Marie Williams, E. Wolf et al.
1 citations
Sensors
Hand Gesture Recognition Systems
1.94
article

Evaluation of Commercial Camera-Based Solutions for Tracking Hand Kinematics

Christopher Vogel, Derek G. Kamper, Marie Williams, E. Wolf, Alexander H. Sprague
article en
1 citations

Abstract

Tracking hand kinematics is essential for numerous clinical and scientific applications. Markerless motion capture devices have advantages over other modalities in terms of calibration, set up, and overall ease of use; however, their accuracy during dynamic tasks has not been fully explored. This study examined the performance of two popular markerless systems, the Leap Motion Controller 2 (LM2) and MediaPipe (MP), in capturing joint motion of the digits. Data were compared to joint motion collected from a marker-based multi-camera system (Vicon). Eleven participants performed six tasks with their dominant right hand at three movement speeds while all three devices simultaneously captured the position of hand landmarks. Using these data, digit joint angles were calculated. The root mean squared error (RMSE) and correlation coefficient (<i>r</i>) relative to the Vicon angles were computed for LM2 and MP. LM2 achieved a lower error (<i>p</i> < 0.001, mean RMSE = 14.8°) and a higher correlation (<i>p</i> = 0.007, mean <i>r</i> = 0.58) than the MP system (mean RMSE = 22.5°, mean <i>r</i> = 0.45). Greater movement speed led to significantly higher RMSE (<i>p</i> < 0.001) and lower <i>r</i> (<i>p</i> < 0.001) for MP but not for LM2. Error was substantially greater for the proximal interphalangeal joint than for other finger joints, although <i>r</i> values were higher for this joint. Overall, the LM2 and MP systems were able to capture motion at the joint level across digits for a variety of tasks in real time, although the level of error may not be acceptable for certain applications.

SensorsVol. 25(18)
University of North Carolina at Chapel Hill (US), North Carolina State University (US)
National Institutes of Health, National Institute on Disability, Independent Living, and Rehabilitation Research
Openalex Percentile: Top 13%
Hand Gesture Recognition Systems
1.94
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.