Bilateral comparison of 10 pF and 100 pF standards (ongoing BIPM key comparisons BIPM.EM-K14.a and 14.b) between the CENAM (Mexico) and the BIPM

Main text This report presents the results of a bilateral comparison between the CENAM, Mexico, and the BIPM, which was carried out using two 10 pF and two 100 pF travelling standards belonging to the BIPM, following an "A-B-A" pattern. The comparison at 10 pF forms part of the ongoing BIPM key comparison BIPM.EM-K14.a and that at 100 pF of the ongoing BIPM key comparison BIPM.EM-K14.b, where BIPM is the pilot laboratory for both comparisons. The standards were measured during a total time of 19 weeks, from January to May 2025. The measurand of this comparison was the two terminal-pair capacitance of the travelling capacitors at frequencies of 1000 Hz and 1592 Hz, and measuring voltages of 50 V and 100 V (rms) for the 10 pF standards and 10 V for the 100 pF standards. The results from the CENAM and the BIPM agree within a difference smaller than the relative expanded uncertainty of the comparison. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

Authors

Institutions

Publication Details

Journal
Metrologia
Published
2025-01-01
DOI
https://doi.org/10.1088/0026-1394/62/1a/01005
Primary Topic
Scientific Measurement and Uncertainty Evaluation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bilateral comparison of 10 pF and 100 pF standards (ongoing BIPM key comparisons BIPM.EM-K14.a and 14.b) between the CENAM (Mexico) and the BIPM

Alepth H. Pacheco-Estrada, P. Gournay, Jorge Moreno
Metrologia
Scientific Measurement and Uncertainty Evaluation
article

Bilateral comparison of 10 pF and 100 pF standards (ongoing BIPM key comparisons BIPM.EM-K14.a and 14.b) between the CENAM (Mexico) and the BIPM

Alepth H. Pacheco-Estrada, P. Gournay, Jorge Moreno
article en

Abstract

Main text This report presents the results of a bilateral comparison between the CENAM, Mexico, and the BIPM, which was carried out using two 10 pF and two 100 pF travelling standards belonging to the BIPM, following an "A-B-A" pattern. The comparison at 10 pF forms part of the ongoing BIPM key comparison BIPM.EM-K14.a and that at 100 pF of the ongoing BIPM key comparison BIPM.EM-K14.b, where BIPM is the pilot laboratory for both comparisons. The standards were measured during a total time of 19 weeks, from January to May 2025. The measurand of this comparison was the two terminal-pair capacitance of the travelling capacitors at frequencies of 1000 Hz and 1592 Hz, and measuring voltages of 50 V and 100 V (rms) for the 10 pF standards and 10 V for the 100 pF standards. The results from the CENAM and the BIPM agree within a difference smaller than the relative expanded uncertainty of the comparison. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

MetrologiaVol. 62(1A)
Centro Tecnológico del Mar (ES), Bureau international des poids et mesures (FR)
Openalex Percentile: Top 75%
Scientific Measurement and Uncertainty Evaluation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Bilateral comparison of 10 pF and 100 pF standards (ongoing BIPM key comparisons BIPM.EM-K14.a and 14.b) between the CENAM (Mexico) and the BIPM — Alepth H. Pacheco-Estrada, P. Gournay, et al. · Metrologia (2025) | TGRS Research Map | TGRS