Full-scale experimental study on tunnel pressure waves caused by an urban train with various air-intake statuses of air-conditioning units

Urban railways alleviate traffic congestion and enhance transportation efficiency. The operation of trains in tunnels can cause significant pressure waves, resulting in passenger discomfort and auditory damage. Therefore, airtight train configurations were employed to mitigate interior pressure fluctuation. To ensure interior air quality, controlled ventilation through air-conditioning units (ACUs) is required. However, during tunnel operations, pressure waves enter the carriage through ACUs, thereby affecting the interior pressure. Considering that the on-off plates of air intakes may malfunction, the influence of tunnel pressure waves on the auditory comfort of passengers is worth investigating. In this study, a full-scale test was conducted to investigate the spatiotemporal distribution characteristics of the interior/exterior pressure variation induced by trains with different lengths passing through tunnels at multiple speeds. The ACU air intake operates in three states: automatic control (closed), 1/4 open, and fully open. An inverse correlation was observed between train length and interior/exterior pressure variation. Compared with the driver's cab, the interior pressure of the passenger compartments was more affected by the train length (with a difference of approximately 30%). The operational state of ACU air intakes significantly impacts interior pressure variations, with closed intakes effectively reducing fluctuations, whereas opening size demonstrated limited influence. Both the amplitude and variation of the interior/exterior pressure exhibited positive correlations with train speed. These findings inform optimized ACU intake control strategies for enhancing passenger auditory comfort.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2025-09-01
DOI
https://doi.org/10.1063/5.0282794
Citations
1
Primary Topic
Aerodynamics and Fluid Dynamics Research
Type
article
Field-Weighted Citation Impact
4.99
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Full-scale experimental study on tunnel pressure waves caused by an urban train with various air-intake statuses of air-conditioning units

Yundong Han, Junhao Song, Yuhan Guo, Shuanbao Yao et al.
1 citations
Physics of Fluids
Aerodynamics and Fluid Dynamics Research
4.99
article

Full-scale experimental study on tunnel pressure waves caused by an urban train with various air-intake statuses of air-conditioning units

Yundong Han, Junhao Song, Yuhan Guo, Shuanbao Yao, Jiqiang Niu, Yangyang Chen, Dawei Chen
article en
1 citations

Abstract

Urban railways alleviate traffic congestion and enhance transportation efficiency. The operation of trains in tunnels can cause significant pressure waves, resulting in passenger discomfort and auditory damage. Therefore, airtight train configurations were employed to mitigate interior pressure fluctuation. To ensure interior air quality, controlled ventilation through air-conditioning units (ACUs) is required. However, during tunnel operations, pressure waves enter the carriage through ACUs, thereby affecting the interior pressure. Considering that the on-off plates of air intakes may malfunction, the influence of tunnel pressure waves on the auditory comfort of passengers is worth investigating. In this study, a full-scale test was conducted to investigate the spatiotemporal distribution characteristics of the interior/exterior pressure variation induced by trains with different lengths passing through tunnels at multiple speeds. The ACU air intake operates in three states: automatic control (closed), 1/4 open, and fully open. An inverse correlation was observed between train length and interior/exterior pressure variation. Compared with the driver's cab, the interior pressure of the passenger compartments was more affected by the train length (with a difference of approximately 30%). The operational state of ACU air intakes significantly impacts interior pressure variations, with closed intakes effectively reducing fluctuations, whereas opening size demonstrated limited influence. Both the amplitude and variation of the interior/exterior pressure exhibited positive correlations with train speed. These findings inform optimized ACU intake control strategies for enhancing passenger auditory comfort.

Physics of FluidsVol. 37(9)
Qingdao Center of Resource Chemistry and New Materials (CN), Southwest Jiaotong University (CN)
Openalex Percentile: Top 5%
Aerodynamics and Fluid Dynamics Research
4.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.