Impact of pupillary dilation on the efficacy of laser peripheral iridotomy

Purpose: To assess outcomes of laser peripheral iridotomy (LPI) procedures following dilation by evaluating the pressure difference across the iris posterior-anterior chamber resulting from varying hole sizes and locations. Methods: Using an anterior segment optical coherence tomography (AS-OCT) image, we created a 3-D finite element model of the iris. We then manually identified a dilator region where the dilator stress was applied to simulate pupillary dilation. To mimic LPI, we made a hole of 200 microns in diameter near the pupillary margin, at the mid-periphery, and at the periphery of the iris. Using computational fluid dynamics methods, we computed the pressure difference developed by the hole before and after pupil dilation at each location. This process was then repeated with a hole of 400 microns in diameter. Results: The pressure difference developed across a 200-micron hole when the hole was placed near the pupil, at the iris mid-periphery, and near the iris periphery was 0.85 Pa, 0.80 Pa, and 0.92 Pa, respectively. Following pupil dilation, the pressure difference increased in all cases. For the compressible iris model, the pressure increased by 4.70%, 63.75%, and 52.17% near the pupil, at the iris mid-periphery, and near the iris periphery, respectively. For the nearly incompressible model, the pressure increased by 7.06%, 51.25%, and 55.43% near the pupil, at the iris mid-periphery, and near the iris periphery, respectively. Across a 400-micron diameter hole, the pressure difference developed was extremely small (< 0.1 Pa) across all cases, both before and following dilation. Conclusion: While LPI offers a solution for narrow or closed anterior chamber angles, in some patient populations the angles remain occludable following LPI. One possible reason could be attributed to the additional pressure difference across the anterior and posterior chamber due to the change in LPI hole size following dilation-inducediris deformation. Our study shows that the LPI hole size/location affects the pressure difference in both compressible and nearly incompressible irides.

Authors

Institutions

Publication Details

Journal
Artificial Intelligence in Vision and Ophthalmology
Published
2025-09-15
DOI
https://doi.org/10.35119/aivo.v1i1.140
Citations
2
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
3.41

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of pupillary dilation on the efficacy of laser peripheral iridotomy

Anup Pant, Frederick Sebastian, Rouzbeh Amini, Syril Dorairaj et al.
2 citations
Artificial Intelligence in Vision and Ophthalmology
Glaucoma and retinal disorders
3.41
article

Impact of pupillary dilation on the efficacy of laser peripheral iridotomy

Anup Pant, Frederick Sebastian, Rouzbeh Amini, Syril Dorairaj, Keyvan Amini Khoiy, Rodolfo Repetto
article en
2 citations

Abstract

Purpose: To assess outcomes of laser peripheral iridotomy (LPI) procedures following dilation by evaluating the pressure difference across the iris posterior-anterior chamber resulting from varying hole sizes and locations. Methods: Using an anterior segment optical coherence tomography (AS-OCT) image, we created a 3-D finite element model of the iris. We then manually identified a dilator region where the dilator stress was applied to simulate pupillary dilation. To mimic LPI, we made a hole of 200 microns in diameter near the pupillary margin, at the mid-periphery, and at the periphery of the iris. Using computational fluid dynamics methods, we computed the pressure difference developed by the hole before and after pupil dilation at each location. This process was then repeated with a hole of 400 microns in diameter. Results: The pressure difference developed across a 200-micron hole when the hole was placed near the pupil, at the iris mid-periphery, and near the iris periphery was 0.85 Pa, 0.80 Pa, and 0.92 Pa, respectively. Following pupil dilation, the pressure difference increased in all cases. For the compressible iris model, the pressure increased by 4.70%, 63.75%, and 52.17% near the pupil, at the iris mid-periphery, and near the iris periphery, respectively. For the nearly incompressible model, the pressure increased by 7.06%, 51.25%, and 55.43% near the pupil, at the iris mid-periphery, and near the iris periphery, respectively. Across a 400-micron diameter hole, the pressure difference developed was extremely small (< 0.1 Pa) across all cases, both before and following dilation. Conclusion: While LPI offers a solution for narrow or closed anterior chamber angles, in some patient populations the angles remain occludable following LPI. One possible reason could be attributed to the additional pressure difference across the anterior and posterior chamber due to the change in LPI hole size following dilation-inducediris deformation. Our study shows that the LPI hole size/location affects the pressure difference in both compressible and nearly incompressible irides.

Artificial Intelligence in Vision and OphthalmologyVol. 1(1)
University of Akron (US), Northeastern University (US), WinnMed (US), Mayo Clinic in Florida (US), University of Genoa (IT)
National Science Foundation, Glaucoma Research Foundation, BrightFocus Foundation
Openalex Percentile: Top 7%
Glaucoma and retinal disorders
3.41
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.