Time-Domain Differential Protection for Photovoltaic Distribution Networks Based on Hellinger Distance

With the advancement of 5G communication technology, differential protection has gained a solid foundation for application in distribution networks. However, frequency-domain differential protection methods based on Fourier transform are susceptible to errors caused by decaying DC components, while most existing time-domain pilot protection methods lack discussion on impacts from non-ideal conditions. To address these issues, this paper proposes a Hellinger distance-based time-domain pilot protection method for active distribution networks. First, the Hellinger distance algorithm is introduced, and two key indices—the Hellinger Distance Parameter (HDP) between current sequences from both ends and the threshold THR—are designed. Furthermore, an Enhanced HDP (EHDP) criterion incorporating a dynamic coefficient J is proposed to prevent maloperation caused by current transformer (CT) saturation. Finally, the proposed protection method is validated in PSCAD/EMTDC simulation software. Comprehensive comparative studies are conducted under various fault types, locations, transition resistances, and non-ideal conditions. Simulation results demonstrate the method's strong adaptability in active distribution networks and its robustness against non-ideal influences.

Authors

Institutions

Publication Details

Published
2025-06-20
DOI
https://doi.org/10.1109/icesep66633.2025.11155278
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Time-Domain Differential Protection for Photovoltaic Distribution Networks Based on Hellinger Distance

Yabo Zhu, Ziyue Wang, Xiaolv He, Chenwei Tian et al.
Smart Grid Security and Resilience
article

Time-Domain Differential Protection for Photovoltaic Distribution Networks Based on Hellinger Distance

Yabo Zhu, Ziyue Wang, Xiaolv He, Chenwei Tian, Yanting Li, Zhipeng Su
article en

Abstract

With the advancement of 5G communication technology, differential protection has gained a solid foundation for application in distribution networks. However, frequency-domain differential protection methods based on Fourier transform are susceptible to errors caused by decaying DC components, while most existing time-domain pilot protection methods lack discussion on impacts from non-ideal conditions. To address these issues, this paper proposes a Hellinger distance-based time-domain pilot protection method for active distribution networks. First, the Hellinger distance algorithm is introduced, and two key indices—the Hellinger Distance Parameter (HDP) between current sequences from both ends and the threshold THR—are designed. Furthermore, an Enhanced HDP (EHDP) criterion incorporating a dynamic coefficient J is proposed to prevent maloperation caused by current transformer (CT) saturation. Finally, the proposed protection method is validated in PSCAD/EMTDC simulation software. Comprehensive comparative studies are conducted under various fault types, locations, transition resistances, and non-ideal conditions. Simulation results demonstrate the method's strong adaptability in active distribution networks and its robustness against non-ideal influences.

China University of Mining and Technology (CN)
Openalex Percentile: Top 69%
Smart Grid Security and Resilience
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.