Available Service Life Analysis of Surge Arrester Based on Cross-Provincial Decommission Records

Surge arrester play an indispensable and crucial role in protecting the power grid from lightning and overvoltage threats. This study performs a statistical analysis on the available service life(ASL) of Surge arrester based on provincial-level decommission records in China. Key findings reveal a significant discrepancy between actual service life (9.5-25 years) and theoretical technical lifespan (12.4-30 years), with voltage-level-specific variations observed. The ASL distribution demonstrates a significant right-skewed pattern, peaking between 13-20 years. Manufacturing quality emerges as the primary contributor to premature retirement, reducing average lifespan to 7.15 years in affected units. The analysis identifies concurrent occurrence of clustered retirement events and premature failures, with regions and voltage levels exhibiting impacts on the ASL. The established ASL distribution models offer a heuristic references for remain usefullife prediction and infrastructure life cycle analysis in power transmission systems.

Authors

Institutions

Publication Details

Published
2025-06-20
DOI
https://doi.org/10.1109/icesep66633.2025.11155446
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Available Service Life Analysis of Surge Arrester Based on Cross-Provincial Decommission Records

Haoran Li, Wenqi Li, Yundong Gu
Advanced Sensor and Control Systems
article

Available Service Life Analysis of Surge Arrester Based on Cross-Provincial Decommission Records

Haoran Li, Wenqi Li, Yundong Gu
article en

Abstract

Surge arrester play an indispensable and crucial role in protecting the power grid from lightning and overvoltage threats. This study performs a statistical analysis on the available service life(ASL) of Surge arrester based on provincial-level decommission records in China. Key findings reveal a significant discrepancy between actual service life (9.5-25 years) and theoretical technical lifespan (12.4-30 years), with voltage-level-specific variations observed. The ASL distribution demonstrates a significant right-skewed pattern, peaking between 13-20 years. Manufacturing quality emerges as the primary contributor to premature retirement, reducing average lifespan to 7.15 years in affected units. The analysis identifies concurrent occurrence of clustered retirement events and premature failures, with regions and voltage levels exhibiting impacts on the ASL. The established ASL distribution models offer a heuristic references for remain usefullife prediction and infrastructure life cycle analysis in power transmission systems.

North China Electric Power University (CN)
Openalex Percentile: Top 69%
Advanced Sensor and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Available Service Life Analysis of Surge Arrester Based on Cross-Provincial Decommission Records — Haoran Li, Wenqi Li, et al. · (2025) | TGRS Research Map | TGRS